9 CONFIGURATION MENU
0460 896 274
- 60 -
© ESAB AB 2013
the beginning. You can always go to the “MULTIPLE WIRE FEEDERS” menu and check the
ID number of the connected wire feed units by pressing the trigger switch.
On the CONNECTED WIRE FEEDERS ID row, you can see the ID number of all connected
wire feed units.
9.12
Quality functions
Main menu → Configuration menu → Quality functions
The conditions for logging completed welds are set under Quality functions in the
Configuration menu.
Select the row and press ENTER. If ON is selected, each weld will be stored as a text file
with the extension .aqd, with a new file per day. The following information is registered here:
•
Time of welding start
•
Duration of welding
•
Maximum, minimum and average current during welding
•
Maximum, minimum and average voltage during welding
•
Maximum, minimum and average output during welding
Read more about the quality function in the "Quality functions" section.
9.13
Maintenance
Main menu → Configuration menu → Maintenance
In this menu you set how often the contact tip is to be changed. Specify the number of weld
starts after which the tip is to be changed by selecting the CONTACT TIP CHANGE
INTERVAL row and pressing ENTER. Then adjust the plus/minus knobs until you arrive at
your value. When the interval has been passed, fault code 54 is displayed in the error log.
Reset by pressing the RESET soft key.
When TOTAL RUNNING TIME LIMIT is selected instead of the number of starts, an
authorised ESAB service technician is contacted.
Summary of Contents for Aristo U82
Page 1: ...Aristo Instruction manual 0460 896 274 GB 20130902 Valid from program version 1 15A U82 ...
Page 80: ...MENU STRUCTURE 0460 896 274 80 ESAB AB 2013 MENU STRUCTURE ...
Page 81: ...MENU STRUCTURE 0460 896 274 81 ESAB AB 2013 ...
Page 82: ...MENU STRUCTURE 0460 896 274 82 ESAB AB 2013 ...
Page 83: ...MENU STRUCTURE 0460 896 274 83 ESAB AB 2013 ...
Page 84: ...MENU STRUCTURE 0460 896 274 84 ESAB AB 2013 ...