10 TOOLS
0460 896 274
- 64 -
© ESAB AB 2013
The following information can be read in the error log menu:
•
The error number of the error
•
The date on which the error has occurred
•
The time at which the error has occurred
•
The unit in which the error has occurred
•
The error's error management code
Units
1 = cooling unit
4 = remote control unit
2 = power source
5 = AC-unit
3 = wire feed unit
8 = control panel
10.1.1
Error code descriptions
Fault code
Description
1
Program memory error, (EPROM)
There is a fault in the program memory.
This fault does not disable any functions.
Action:
Restart the machine. If the fault persists, send for a service
technician.
2
Microprocessor RAM error
The microprocessor is unable to read/write from/to a certain memory position
in its internal memory.
This fault does not disable any functions.
Action:
Restart the machine. If the fault persists, send for a service
technician.
3
External RAM error
The microprocessor is unable to read/write from/to a certain memory position
in its external memory.
This fault does not disable any functions.
Action:
Restart the machine. If the fault persists, send for a service
technician.
Summary of Contents for Aristo U82
Page 1: ...Aristo Instruction manual 0460 896 274 GB 20130902 Valid from program version 1 15A U82 ...
Page 80: ...MENU STRUCTURE 0460 896 274 80 ESAB AB 2013 MENU STRUCTURE ...
Page 81: ...MENU STRUCTURE 0460 896 274 81 ESAB AB 2013 ...
Page 82: ...MENU STRUCTURE 0460 896 274 82 ESAB AB 2013 ...
Page 83: ...MENU STRUCTURE 0460 896 274 83 ESAB AB 2013 ...
Page 84: ...MENU STRUCTURE 0460 896 274 84 ESAB AB 2013 ...