10 TOOLS
0460 896 274
- 66 -
© ESAB AB 2013
Fault code
Description
16
High open-circuit voltage
The open-circuit voltage has been too high.
Action:
Turn off the mains power supply to reset the unit. If the fault persists,
send for a service technician.
17
Lost contact with an other unit
The current activities will be stopped and the welding start is prevented.
This error can be caused by a brake in the connection (i.e. the CAN cable)
between the welding data unit and an other unit. Which unit it concerns is
displayed in the error log.
Action:
Check the CAN cabling. If the error persists, send for a service
technician.
19
Memory error in battery powered data memory RAM
The battery has lost voltage
Action:
Turn off the mains power supply to reset the unit. The control panel
is reset. The settings are in English, with MIG/MAG, SHORT/SPRAY, Fe,
CO2, 1.2 mm. If the error persists, send for a service technician.
22
Transmitter buffer overflow
The control panel is unable to transmit information to the other units at a
sufficiently high speed.
Action:
Turn off the mains power supply to reset the unit.
23
Receiver buffer overflow
The control panel is unable to process information from the other units at a
sufficiently high speed.
Action:
Turn off the mains power supply to reset the unit.
25
Incompatible weld data format
Attempt to store weld data on a USB memory. The USB memory has a
different data format that the weld data memory.
Action:
Use a different USB memory.
26
Program error
Something has prevented the processor from performing its normal tasks in
the program.
The program restarts automatically. The current welding process will be
stopped. This fault does not disable any functions.
Action:
Review the handling of welding programs during welding. If the error
is repeated, send for a service technician.
28
Program data lost
Program execution does not work.
Action:
Turn off the mains power supply to reset the unit. If the error
persists, send for a service technician.
40
Incompatible units
Incorrect wire feed unit is connected. Start is prevented
Action:
Connect the correct wire feed unit.
Summary of Contents for Aristo U82
Page 1: ...Aristo Instruction manual 0460 896 274 GB 20130902 Valid from program version 1 15A U82 ...
Page 80: ...MENU STRUCTURE 0460 896 274 80 ESAB AB 2013 MENU STRUCTURE ...
Page 81: ...MENU STRUCTURE 0460 896 274 81 ESAB AB 2013 ...
Page 82: ...MENU STRUCTURE 0460 896 274 82 ESAB AB 2013 ...
Page 83: ...MENU STRUCTURE 0460 896 274 83 ESAB AB 2013 ...
Page 84: ...MENU STRUCTURE 0460 896 274 84 ESAB AB 2013 ...