10 TOOLS
0460 896 274
- 76 -
© ESAB AB 2013
Select an alternative that is displayed in the
list and press ENTER.
Select in the same way for SHIELDING GAS
and press ENTER.
Select in the same way for WIRE DIAMETER
and press ENTER.
Select the SYNERGIC DESIGN SCHEDULE 1 row and press STORE.
The operation is now complete – a synergic line has been defined.
NOTE!
A corresponding short-/sprayarc synergy is needed for each pulsing instance.
When you create a new synergic line for the pulsing method, you therefore always receive a
warning message stating that a corresponding line has not been created for the
short-/sprayarc method. The message reads:
WARNING! No corresponding synergic line for
short-/sprayarc.
10.8.3
Create your own wire/gas alternative
The lists of wire/gas alternatives can be extended with up to ten alternatives of your own. At
the bottom of each list there is a blank row (---). By positioning the cursor on this row and
pressing ENTER, you gain access to a keyboard that enables you to enter your own
alternatives.
Select the row --- and press ENTER.