© ESAB AB 2011
- 16 -
ba58ae
Welding gun
S
Cleaning and replacement of the welding gun's wear parts should take place at
regular intervals in order to achieve trouble-free wire feed. Blow the wire guide
clean regularly and clean the contact tip.
8
FAULT TRACING
Try these recommended checks and inspections before sending for an authorised
service technican.
Type of fault
Actions
No arc
S
Check that the mains power supply switch is turned on.
S
Check that the welding current supply and return cables are
correctly connected.
S
Check that correct current value is set.
S
Check to see whether the MCB has tripped.
Welding current is interrupted
during welding
S
Check whether the thermal overload trip has been triggered
(indicated by the orange lamp on the front).
S
Check the main power supply fuses.
Thermal overload trips
trigger frequently
S
Check to see whether the air filters are clogged.
S
Make sure that you are not exceeding the rated data for the
power source (i.e. that the unit is not being overloaded).
Poor welding performance
S
Check that the welding current supply and return cables are
correctly connected.
S
Check that the correct current value is set.
S
Check that the correct welding wires are being used.
S
Check the main power supply fuses.
9
ORDERING OF SPARE PARTS
Repair and electrical work should be performed by an authorized ESAB service
personnel. Use only ESAB original replacement and wear parts.
Mig 410, Mig 510 is designed and tested in accordance with the international and Euro
pean standards IEC/EN 60974-1 and IEC/EN 60974-10. It is the obligation of the servi
ce unit which has carried out the service or repair work to make sure that the product
still conforms to the said standard.
When ordering replacement parts, order by part number and part name, as
illustrated on the figure. Always provide the series or serial number on the unit on
which the parts will be used. The serial number is stamped on the rating plate.
US
Summary of Contents for Origo Mig 410
Page 46: ... 46 p ...
Page 47: ... ESAB AB 2011 Nettoyage Limpieza Cleaning 47 ba52clean ...
Page 48: ... ESAB AB 2011 Schéma Esquema Schematic diagram 48 ba58ea Mig 410 230 500V ...
Page 49: ... ESAB AB 2011 49 ba58ea Mig 410 230 500V ...
Page 50: ... ESAB AB 2011 50 ba58ea Mig 510 230 500 V ...
Page 51: ... ESAB AB 2011 51 ba58ea Mig 510 230 500 V ...
Page 53: ... ESAB AB 2011 53 ba58c Mig 510 ...
Page 57: ... 57 notes NOTES ...