6.10 high / low cut current modes and mark mode
A remote contact connecting 115V AC from J1-R to J1-S places the Pilot Arc in High by operating K8. Note, that for this func
-
tion to operate, the Pilot Arc Hi/Lo switch on the front panel must be in the “LO” position.
The EPP-450 is placed in the Marking mode when a remote contact connecting 115V AC from J1-R to J1-C operates K11. In
the Marking mode, a normally closed contact on K11 opens turning off K10. When K10 turns off, the Boost supply is discon
-
nected lowering the normal Cutting Mode 430V DC Open Circuit Voltage to 360VDC for Marking. A normally open contact
on K11 activates K12. K12 connects the I (min) resistors necessary for stabilizing the low currents required for marking. In
the Cutting mode, the minimum stable output current is 50A in the high current range, 35A in the low current range and
10A in the marking mode. In the marking mode, the normally closed contacts K11(3, 9) and K11(1, 7) open. This deactivates
K13 and K14 placing the power source in the low current range.
LO
HI
5
6
H
1
K11
CUT/
MARK
10 2W
J6-A
A
PILOT ARC
FN4
J1-R
J1
-M
5
115V
G
A
J1-S
1µF
4
1
2
AC
CUT
A
J1-C
TB9-18
8
3
MARK
K11
3
9
H
LO
5
8
K13
BOOST
R70
J1-Z
TB1-8
TB9-13
K8
600V
K10
N
K11
6
9
K3
J6-B
I(min) RESISTORS
K12
HI/LO
TB8-7
S1
TB1-7
HI
WHT
TB8-1
L3
K4
T3
J1-T
CUT
CURRENT
RANGE
K13
RED
MOVE RED WIRE FROM
TB8-1 TO TB8-2 FOR
FOR HI CURRENT RANGE
TB8-2
LO
HI
K13
3
9
PILOT
ARC
FAN
M5
CONTA
C
TOR SIGNA
L
PL2
N
7
K11
K14
115 VAC
P5-1
T7
SEC 40VCT
20V
20V
Z BIAS
P5-2
P5-3
PRI 120V
PCB3 Right
PWM/Gate Drive
N
6
9
K13
D
SEE PAGE 2
PCB10 P1-2
TB8-7
TB1-7
TB8-8
N
HIGH/LOW CUT CURRENT MODES & MARK MODE