Code
Solution
Cause
Problem
15
Bus charging fault
Under voltage on the primary
bus.
Check the bus charger.
19
Torch trigger early
engagement
Torch trigger depressed at
power up.
Check the trigger.
20
No return at PIP (Parts In
Place) check of consum
ables.
The piston was not
withdrawn when air was
released.
Check/clean consumables.
Check the compressed air
supply.
21
No unbroken current path at
PIP (Parts In Place) check of
consumables.
The piston did not fall back
when the air supply was
removed.
Check/clean consumables.
8
ORDERING SPARE PARTS
Repair and electrical work should be performed by an authorised ESAB service
technician. Use only ESAB original spare and wear parts.
Powercut 1300/1600 is designed and tested in accordance with the international and
European standards 60974-1 and 60974-10. It is the obligation of the service unit
which has carried out the service or repair work to make sure that the product still
conforms to the said standard.
Always provide the serial number of the unit on which the parts will be used. The
serialnumber is stamped on the units measuring plate.
Spare parts may be ordered through your nearest ESAB dealer, see the last page of
this publication.