© ESAB AB 2011
- 9 -
bp16ea
4.2
Mains power supply
Make sure that the power source is connected to the correct supply voltage and that
it is protected by the correct fuse rating. The outlet shall have a protectiv earth
connection.
Rating plate with supply connection data
Recommended fuse sizes and minimum cable area
Powercut 1300
Powercut 1600
Mains voltage
400 V, 50 Hz
400 V, 50 Hz
Mains cable area
mm
2
4 G 6
4 G 6
Phase current
I
1eff
18 A
20 A
Fuse, anti-surge
25 A
30 A
NOTE!
The mains cable areas and fuse sizes as shown above are in accordance with Swedish
regulations. Use the power source in accordance with the relevant national regulations.
WARNING
Make sure the power source is switched off before removing the fuse.
4.3
Input air connection
Connect your air supply to the inlet connection of the filter.
GB