-- 25 --
bu12d04a
Burnback Time
STOP DATA SYNERGIC MODE
Position the cursor
on the line
BURNBACK TIME.
Set it to 0.11 s using
one of the
plus/minus buttons.
CRATERFILL
YES
TIME
:
1.5 s
FINAL WIRE SPEED:
118 in/min (3.0 m/min)
BURNBACKTIME:
0.11 s
GASPOSTFLOW:
0.5 s
CRATR
D
FILL
HOT
D
START
4--
STROKE
QUIT
Gas Post--Flow
Use this to set the time for which the gas continues to flow after welding is complete.
STOP DATA SYNERGIC MODE
Position the cursor
on the line GAS
POST--FLOW. Set
it to 2.0 s using one
of the plus/minus
buttons.
CRATERFILL
YES
TIME
:
1.5 s
FINAL WIRE SPEED:
118 in/min (3.0 m/min)
BURNBACKTIME:
0.11 s
GASPOSTFLOW:
2.0 s
CRATR
D
FILL
HOT
D
START
4--
STROKE
QUIT
This completes the stop data settings and means that all the weld data settings for