-- 36 --
bu12d04a
4.4.2
Weld Data Settings
Use the settings menu to set the values of the various welding parameters.
We will make the following settings:
S
CURRENT = 200 A
S
SLOPE--UP TIME = 2.0 s
S
SLOPE--DOWN TIME = 1.4 s
S
GAS PRE--FLOW = 3.0 s
S
GAS POST--FLOW = 5.0 s
Press the MENU key, call up the settings menu by pressing the SETUP button.
Current
WELD DATA SETTING
Position the cursor
on the line for
CURRENT.
Use one of the
plus/minus buttons
to set the value to
200 A.
CURRENT:
200 A
SLOPE UP TIME:
4.0 s
SLOPE DOWN TIME:
6.0 s
GASPREFLOW:
2.5 s
GASPOSTFLOW:
3.3 s
GAS
PURGE
4
STROKE
QUIT
Slope--up and Slope--down
The slope--up and slope--down parameters are each connected to a plus/minus
button. The upper key is used for setting of slope--up, and the lower button is used
for setting of slope--down.
WELD DATA SETTING
Place the cursor on
the row for SLOPE
UP and SLOPE
DOWN TIME. Set
SLOPE UP TIME
to 2.0 s. by
stepping with the
upper plus/minus
button.
CURRENT:
200 A
SLOPE UP TIME
:
# 2.0 s
SLOPE DOWN TIME:
*
6.0 s
GAS PRE--FLOW:
2.5 s
GAS POST--FLOW:
3.3 s
GAS
PURGE
4
STROKE
QUIT