-- 61 --
bu12d04a
9.2.6
STICK Defaults settings
Function intended for future use.
9.2.7
TIG Defaults settings
Function intended for future use.
9.2.8
General Defaults settings
9.2.8.1 Quick Setting (Fast Mode) Limits
MAIN MENU
AUXILIARY FUNCTIONS
CONFIGURATION
GENERAL DEFAULTS
FAST MODE LIMITS
Configuration of a soft button to fast setting occurs in the following way.
GENERAL DEFAULTS -- FAST MODE
Position the cursor
on the line for
button number.
SOFT KEY NUMBER:
1
VOLTAGE:
+ 0.0 V
-- 0.0 V
WIRE SPEED:
+ 0.0 in/min
-- 0.0 in/min
ASSOCIATED WELD DATA:
1
DIP/SPRAY. Fe. CO2,
0.045”...
QUIT
The buttons are numbered 1--4 from left to right. Select the desired button by
indicating its number with the plus/minus buttons.
Then move down with the down--arrow button to the line ”ASSOCIATED WELD
DATA.” Here you can look through the weld data set--ups stored in the weld data
memory. Select the desired weld data number with the plus/minus buttons.
When a weld data set--up is called in via quick position button, it is still possible to
adjust available weld parameters. To restrict the adjustment of these parameters, it is
possible to designate an upper and lower limit for each of them.