-- 72 --
bu12d04a
S
the parameters pulse time, Hot start voltage, Ka, Ki and the slope
parameters must have the
same values
in both weld data numbers.
S
Crater fill data must be saved as weld data number 96, for both methods
(dip/spray and pulse).
4. Define the number of co--ordinates needed, then move on to ”Specifying the
relevant wire--gas combination.”
9.6.2
Specify the Relevant Wire/Gas Combination
Do as follows:
1. Set up the display to handle user--defined synergy lines.
MAIN MENU
AUXILIARY FUNCTIONS
CUSTOM SYNERGIC PARAM
CREATE USER--DEFINED SYNERGY LINES
Position the cursor
on the line WIRE
TYPE
and press ENTER.
WIRE TYPE:
Metal cored Fe
SHIELDING GAS:
Ar+8%CO2
WIRE DIAMETER:
0.045”
STORE NEW LINES FROM
WELD MEMORY
96. 97
DELETE SYNERGIC LINE
QUIT
ENTER
Choose an option from the list displayed (mark the option and press ENTER).
2. Now choose a shielding gas and wire diameter in the same way.
3. Mark the line STORE NEW LINE....and press ENTER.
The process is now complete -- a new synergy line has been defined.
NOTE!
If you want to use the crater fill function when pulse welding then there must be a
corresponding synergic line for dip/spray welding since all crater fill data is based on
dip/spray parameters.
When a new synergy line for pulse welding is created, a warning will always appear
if a corresponding line has not been created for dip/spray welding.
WARNING!
No corresponding synergy line
for dip/spray welding