-- 78 --
bu12d04a
10
APPENDIX
10.1 Setting Ranges and Setting Steps
MIG
Parameter
Setting range
Setting step
Wire feed speed
59--984 in/min
4 in/min
Voltage
8.0--60.0 V
0.25 V
Inductance
0--100%
1%
Pulse current
100--600 A
4 A
Pulse time
1.7 -- 25.5 ms
0.1 ms
Pulse frequency
20 -- 312 Hz
2 Hz
Background current
12--300 A
4 A
Slope time
1--9
1
Ka
0--100%
1%
Ki
0--100%
1%
Gas pre--flow time
0.0--25.0 s
0.1 s
Gas post--flow time
0.0--25.0 s
0.1 s
Burnback time
0.00--1.00 s
0.01 s
Hot start time
0.0--10.0 s
0.1 s
Wire feed speed. Hot start
0.0--787 in/min
4 in/min
Voltage increase. Hot start
0.0--60.0 V
0.25 V
Crater fill time
0.0--10.0 s
0.1 s
Final wire feed speed. Crater fill
59--635 in/min
4 in/min
Final voltage. Crater fill
8.0--60 V
0.25 V
Shake--off pulse
10--120%
1%
Regulator type
Type number 1--12
--
Italicised parameters are not available in synergetic mode.
The parameter
regulator type
does not have a true setting range. In MIG welding it
is possible to choose between twelve different regulator types numbered 1--12.
STICK
Parameter
Setting range
Setting step
Weld current
16--320 A (Aristo 320)
16--450 A (Aristo 450)
1 A
1 A
Arc pressure
0--100%
1%
Italicised parameters are not available in synergetic mode.