SECTION 5
TROUBLESHOOTING
22
G. Inverter Control Board, ICB, Troubleshooting (See Figure 5-3)
Voltage Checks
(+) Probe
(-) Probe
Measurements
P5-8
P5-9
18 V ac
AC Bias
P5-8
P5-10
36 V ac
AC Bias
P5-6
P2-9
12 V dc
DC Bias
P5-5
P2-9
-12 V dc
DC Bias
P5-3
P1-6
5 V dc
Digital Meter Bias
P5-1
P2-9
10 V dc
DC Bias
P4-7
P4-8
115 V ac
MIG Contactor Signal
P4-9
P4-10
24 V ac
Stick Contactor Signal
P2-10
P3-1
72 V dc
Arc Voltage - open circuit
P1-1
P1-2
10 ±0.3 mV
Shunt Signal/100 amps
P1-4
P1-5
10 ±0.3 mV
Meter Signal/100 amps
P3-3
P2-2
12 V dc
MIG Mode Select
0 V dc
Stick Mode Select
P3-9
P3-10
0 V dc
Thermal-Normal
12 V dc
Thermal-Overload
P2-5
P2-2
0 V dc
Steep Slope
5 V dc
Medium Slope
12 V dc
Flat Slope