esatto.house
19
This appliance is supplied set up for Natural
Gas usage. A conversion kit is included with the
product for Universal LPG usage. The conversion
kit contains the appropriate injectors, 1 Brass Test
Point and 1 LPG sticker.
Please follow the procedure below if a conversion
to suit UNIVERSAL LPG is required:
• Remove the hotplate trivets, burner caps and
burner crowns to access the hotplate injectors.
Replace the factory fitted injectors with the
appropriate injectors, as supplied. Refer to
injector orifice table for injector sizes. The
injector size is stamped on the side of the
injector.
• Connect the brass test point adapter (pictured
opposite) using approved gas thread tape or
compound to the elbow fitting.
• Turn on the gas supply and at each new
connection check for leaks using soapy water.
Each hotplate valve should be turned on, one
at a time, and the injector hole blanked off for
several seconds.
• With the appliance operating check the
outlet pressure when all burners of the
appliance are operating at maximum, when
the smallest burner of the appliance is
operating at minimum.
Under these conditions the outlet pressure
should not vary from the nominal outlet
pressure of 2.60kPa by more than ±0.52kPa.
• If the regulator appears to not be performing
satisfactorily then check the following points:
• If the outlet pressure is consistently too low
then the inlet pressure may be too low and
adjustment of an upstream regulator may be
needed, or an upstream regulator or valve with
insufficient flow capacity may be present in the
gas supply line.
• If this is suspected then it may be necessary to
repeat the checks whilst measuring both the
inlet and outlet pressure to determine if the
inlet pressure is in the range 2.75 – 7.00kPa.
• One by one, turn the knobs to minimum and
screw in the bypass screw (accessible when
the knob is removed) until a small stable flame
results; a length of 3-4mm. Turn the knob to
maximum and then back to minimum to ensure
that the correct minimum flame is maintained.
• Attach the LPG sticker to the cooker, near the
gas supply inlet. Cover the Natural Gas label
that is factory fitted.
LPG Conversion