background image

 

  

Issue Date: 23 May 2011 

Version 1.1

 
 

Escort iMiniPlus PDF Logger 

Quick

 User Guide v1.1 

 

 

Escort Verification Technologies, Inc.

 dba 

ESCORT Data Loggers 

 

PO Box 309, 120 Parkway Drive 
Buchanan, VA 24066 
Ph: 540-254-1433 Fax: 540-254-2433   

         

- 3 -

 

          Email: 

techsupport@escortdataloggers.com

 

 

   

1

 

Sp e c if ic a t ion s

 

 

iMiniPlus PDF 8K 

iMiniPlus PDF 16K 

Operating Temperature 

-40°C to +70°C ( -40°F to +158°F) 

-40°C to +70°C ( -40°F to +158°F) 

Product Code 

MU-IN-D-8-L 

MU-IN-D-16-L 

 

MU-OE-D-8-L 

MU-OE-D-16-L 

 

MU-ST-D-8-L 

 

Sensors 

Internal or External options 

Internal or External options 

LCD display  

Large 5 digits  

Large 5 digits  

Start option  

“START” button  

“START” button  

 

  

*"RESTART" feature with ‘START’ button 

Stop option  

“STOP” button or PC  

“STOP” button or PC  

Book marking  

YES  

YES  

Continuous Logging mode   YES  

YES  

Display resolution  

0.1 ºC  

0.1 ºC  

Accuracy  

±0.5 ºC[-40 ºC to-10 ºC]  

±0.5 ºC[-40 ºC to-10 ºC]  

 

±0.3 ºC[-10 ºC to+70ºC]  

±0.3 ºC[-10 ºC to+70ºC]  

 

±1.0 ºF [-40°F to +14°F]  

±1.0 ºF [-40°F to +14°F]  

 

±0.6 ºF [+14°F to +158°F]  

±0.6 ºF [+14°F to +158°F]  

Sensor response time 

INT – T90 of 20 min in moving air  

INT – T90 of 20 min in moving air  

 

EXT – T90 of 5 min in moving air 

EXT – T90 of 5 min in moving air 

Log interval  

5 seconds to 18 hours  

5 seconds to 18 hours  

Battery Low icon on LCD  

YES  

YES  

Memory capacity  

8048 

16240 

Communications  

USB  

USB  

Trip counter  

YES  

YES  

Lease counter  

YES  

YES  

High / Low Alarms  

Consecutive 

Consecutive 

 

Non Consecutive 

Non Consecutive 

 

Catastrophe Alarm 

Catastrophe Alarm 

 

Integrator Alarm  

Integrator Alarm 

Start delay after “START” 
button pressed  

1 minute to 4 hours 15 minutes 

1 minute to 4 hours 15 minutes 

File formats 

PDF, LCF, LRF, CSV, SYLK, Text 

PDF, LCF, LRF, CSV, SYLK, Text 

Program Password 
protection  

YES  

YES  

LCD Display  

Latest, Highest, Lowest, Average  

Latest, Highest, Lowest, Average 

 

Time over Specifications  

Time over Specifications  

 

Time under Specifications 

Time under Specifications 

 

Low/ High Alarm  

Low/ High Alarm  

 

Degrees ºF or ºC  

Degrees ºF or ºC  

 
*Restart feature with 'START' button only applicable if previous logged trip has not triggered 'HIGH ALARM' and/or 'LOW 
ALARM'

Summary of Contents for MU-IN-D-16-L

Page 1: ...ification Technologies Inc dba ESCORT Data Loggers PO Box 309 120 Parkway Drive Buchanan VA 24066 Ph 540 254 1433 Fax 540 254 2433 Email techsupport escortdataloggers com Escort iMiniPlus PDF Data Log...

Page 2: ...report contents 9 10 Programming logger with Escort Console 12 10 1 Customizing PDF report and changing details 12 10 2 Programming password 13 10 3 Configure Sensors and Alarm Settings 14 10 3 1 Spec...

Page 3: ...1 0 F 40 F to 14 F 0 6 F 14 F to 158 F 0 6 F 14 F to 158 F Sensor response time INT T90 of 20 min in moving air INT T90 of 20 min in moving air EXT T90 of 5 min in moving air EXT T90 of 5 min in movi...

Page 4: ...Drive Buchanan VA 24066 Ph 540 254 1433 Fax 540 254 2433 4 Email techsupport escortdataloggers com 2 Getting Started What you need A B C D A Escort Console Pro Software Software Disk Software is also...

Page 5: ...Guide v1 1 Escort Verification Technologies Inc dba ESCORT Data Loggers PO Box 309 120 Parkway Drive Buchanan VA 24066 Ph 540 254 1433 Fax 540 254 2433 5 Email techsupport escortdataloggers com 3 Fron...

Page 6: ...ly using default USB drivers iMiniPlus PDF does not require any proprietary software installation to download data from logger after logging trip is finished iMiniPlus PDF normally generates 3 files o...

Page 7: ...Escort Verification Technologies Inc dba ESCORT Data Loggers PO Box 309 120 Parkway Drive Buchanan VA 24066 Ph 540 254 1433 Fax 540 254 2433 7 Email techsupport escortdataloggers com 2 Through the esc...

Page 8: ...e traceable and auditable data record The PDF report can be changed by the user This is contrary to the FDA 21 CFR Part 11 requirements to data security In order to produce secure and traceable record...

Page 9: ...ed ESCORT MPP drive 9 PDF report contents Open double click RECORD PDF You can disable PDF report generation by programming logger with Escort Console software You can also enable or disable certain p...

Page 10: ...tics part includes Highest temperature reading for the current trip Average temperature reading for the current trip Please note if the logger is configured for continuous logging logger memory is get...

Page 11: ...temperature by 0 1 F Duration of out of specification and the list of readings will read the same Page3 of PDF report List of readings Out of specification is a report of how long the logger spent ou...

Page 12: ...nfigure button on the toolbar Program Wizard should start Then click Next Logger should be recognized and displayed 10 1 Customizing PDF report and changing details Click on Next button You can see ed...

Page 13: ...rther access to the iMiniPlus PDF Logger When the password option is enabled a window similar to the following picture will be displayed allowing the user to enter the correct password The Program and...

Page 14: ...e alarm is triggered at 50 1 C not 50 0 C as this value is considered within specification Increment the grouping size used for listing out of specification readings Alarm Type This feature allows the...

Page 15: ...erature and time parameters into one value Total number of degree minutes below specs exceeds the alarm is triggered when the total number of temperature degrees times the minute s duration below the...

Page 16: ...ogger will show d off instead of a temperature value Additionally you will not be able to scroll through the highest lowest average and out of spec readings The word LATEST will flash and if any alarm...

Page 17: ...ge to the date and time on this computer option 10 5 Setting the Start Stop and logging duration 10 5 1 Duration of trip at least If you are using the iMiniPlus PDF Logger to record the temperature of...

Page 18: ...way to start an iMiniPlus PDF Logger is by using the START button With other Escort products it is possible to have a timed or date start as well as a switch start You can also program a delay into t...

Page 19: ...utinely download data from the iMiniPlus PDF Logger otherwise data may be lost Careful selection of the logging interval is required in this case It is possible to download at anytime while the iMiniP...

Page 20: ...was opened with PDF Reader Please note if you can not save PDF Report opened in PDF Reader software using Save As menu item you can always copy file using Windows Explorer and paste it to the desired...

Page 21: ...back one step in the step by step progress and Next takes you to the next step The Next button is preceded by the Download button The Help button will provide description and instruction about the st...

Page 22: ...254 1433 Fax 540 254 2433 22 Email techsupport escortdataloggers com Click on the Finish button 13 Does Console work with PDF file Escort Console neither opens logger PDF report nor creates one Escort...

Reviews: