Features

A. Work Surface Ground LEDs: 

When the green LED is lit, the work
surface is properly grounded. When
red LED is lit, the work surface is not
properly grounded.

B. User Ground LEDs:

When the

green LED is lit, the operator is
properly grounded. When red LED is
lit, the operator is not properly
grounded.

C. Monitored User Ground:

The

banana jack for the wrist strap being
monitored.

D.Work Surface:

The banana jack for

the work surface being monitored.

E. Common Point Ground:

Can be used to ground either user or
work surface.

F. Parking Snap:

When touched by

the wrist strap wearer, this snap will
deactivate the alarm function for six
seconds. This allows time for the
wearer to disconnect the coil cord
from the wristband and “park it” on

Figure 4. Workstation Real Time Continuous Monitor Features

this snap. While parked, the coil cord
disables the alarm function to allow
the wearer to leave the workstation.
The “User Ground” LED will remain
off while cord is parked. Upon
returning and removing the coil cord
from the parking snap, the wearer has
six seconds to hook up to the
wristband before the alarm sounds.

Specifications

RESISTANCE LIMITS

Worksurface limit*

set to 500 megohms

Power Source

120 VAC, 50-60 Hz

Current Drain

<15 mA RMS

Response time to alarm

<50 mS

Standby “parking” snap delay

6 seconds

Long Term Drift

1/2% per decade 
(1st decade is 1 hr)

A

B

E

D

C

F

Temperature

10-40 degrees C°

Field Adjustment

None required

Size

3/4" x 3-1/4" x 4-3/8"

Maintenance and
Calibration†

The Workstation Full Time
Continuous Monitor is solid state and
designed to be maintenance free. The
41116 is calibrated to standards
traceable to NIST. There are no user
adjustments that can be made.
Because of the impedance sensing
nature of the test circuit, special
equipment is required for calibration.
We recommend that calibration be
performed annually, using the #41119
Continuous Monitor Calibration Unit.
The Calibration Unit is a most
important product which allows the
customer to perform NIST traceable
calibration on continuous monitors.
The #41119 is designed to be used on
the shop floor at the workstation,
virtually eliminating downtime,
verifying that the continuous monitor
is operating within tolerances. 

†This cannot be verified with standard DC test
equipment. The Workstation Real Time
Continuous Monitor is an impedance sensing
device and the limits are determined by the
magnitude and angle of the impedance.

*Limit can be varied and set to 1 gigohm
maximum.

© 2006 DESCO INDUSTRIES INC.

Employee Owned

432 NORTHBORO ROAD CENTRAL • MARLBORO, MA 01752 • PHONE (508) 485-7390 • FAX (508) 480-0257 • http://www.esdsystems.com

Summary of Contents for 41116

Page 1: ...re utilizing workstation continuous monitoring to better ensure that their products were manufactured in an ESD controlled environment Full time workstation continuous monitoring is superior to pulsed monitoring as well as periodic testing and can save a significant amount of money in testing costs and rejected product Periodic testing detects failures after ESD sensitive products have been manufa...

Page 2: ...itoring For example during each 2 2 second pulse cycle of a leading constant resistive monitor electrical current is pulsed for only 0 2 seconds followed by an unmonitored interval of 2 seconds This leaves the user wrist strap unmonitored for over 90 of each cycle Damaging static charges can easily occur in the portion of the time in between the pulses The off period of 2 seconds equals 2 billion ...

Page 3: ...ce 120 VAC 50 60 Hz Current Drain 15 mA RMS Response time to alarm 50 mS Standby parking snap delay 6 seconds Long Term Drift 1 2 per decade 1st decade is 1 hr A B E D C F Temperature 10 40 degrees C Field Adjustment None required Size 3 4 x3 1 4 x4 3 8 Maintenance and Calibration The Workstation Full Time Continuous Monitor is solid state and designed to be maintenance free The 41116 is calibrate...

Page 4: ...n the Continuous Monitor will be repaired or replaced free of charge If product credit is issued the amount will be calculated by multiplying the unused portion of the expected five year life times the original unit purchase price Call Customer Service at 508 485 7390 for a Return Material Authorization RMA and proper shipping instructions and address You should include a copy of your original pac...

Reviews: