D. Install the Tester on the bracket
by aligning keyholes on the back of
tester with mounting studs on
bracket. While pushing up on thumb
screw, insert the mounting studs into
the keyholes and slide the tester
down. See Figure 4.

E. Twist the thumb screw clockwise
to secure the tester to the bracket.

F. Attach banana plug from small
cord to jack marked “FOOTPLATE”
on tester.

Figure 4. Installing tester on bracket
and securing tester to bracket

TESTING FOOT GROUNDING
DEVICES WITH MODEL 41220

Conductive shoes or foot grounders
should be worn on both feet. Test
each foot separately to ensure proper
operation and complete protection.

A. Switch toggle switch to “FOOT
STRAP” OR “SHOE”, as
appropriate.

B. Place one foot on the plate. If the
floor is conductive, you may need to
lift the foot you are not testing off of
the floor during this test. Make sure
there is no cord plugged into the
“WRIST STRAP” jack.

THUMB SCREW

C. Touch the test button so that the
unit activates. Hold down for 2-3
seconds.

D. Lighting of the green “PASS”
LED indicates that the foot ground
assemblies are functioning properly.

E. If either “Fail LO” or “Fail HI”
LEDs light, the wearer should
investigate the cause of the failure.

F. Repeat steps A through E with
other foot.

Figure 5. Testing foot grounding
devices with the 41220

PS-2094

Page 3 of 4

Specifications:

Operating Voltage 

100-240 VAC, 50/60 Hz

Current Drain 

<20mA

Test Voltage, Open Circuit 

30 VDC

Equipment Ground Resistance

Limit

1 kilohm

Resistance Limits, Wrist Strap

750 kilohms to 10 megohms

Resistance Limits, Foot Strap

750 kilohms to 35 megohms

Resistance Limits, Shoes 

750 kilohms to 1 gigohm

Tolerance On All Limits 

±10%

Size

1 x 5 x 7" 
(2.54 x 12.7 x 17.78cm)

Weight 

1 lb

Line Cord 

5' long, 18-3 AWG

Calibration

The model 41220 is calibrated to
NIST traceable standards. We
recommend that calibration is
performed annually to ensure that
the Tester is operating within limits.
We offer a calibration unit that is
specifically designed to simplify the
calibration procedure. This unit is
sold as item 41230.  The Calibration
Unit comes calibrated to NIST
traceable standards.  For additional
information on the 41230, ask for
Tech Brief PS-2006.

Consider adding the 41220 to your list
of “test equipment that shall be selected
to make measurements of appropriate
properties of the technical requirements
that are incorporated into the ESD
program plan” as required by
paragraph 6.1.3.1 of ANSI/ESD S20.20.

© 2005 DESCO INDUSTRIES INC.

Employee Owned

Summary of Contents for 41220

Page 1: ...uate current limiting resistance and that there is continuity from one s skin to earth ground The Model 41220 also detects excessively dry skin poorly fitting wrist straps and intermittent wrist straps and coil cords The Model 41220 includes a number of innovations Outlet Wiring Verification When plugged into an AC outlet the yellow lamp lights if the polarity is correct and the path to earth grou...

Page 2: ... Multi Range Tester B Plug the plate s ground cord into the jack on the left hand side of the unit Figure 3 Testing foot grounding devices with the 41220 41213 C Switch toggle switch to FOOT STRAP OR SHOE as appropriate D Place one foot on the plate If the floor is conductive you may need to lift the foot you are not testing off of the floor during this test Make sure there is no cord plugged into...

Page 3: ... the wearer should investigate the cause of the failure F Repeat steps A through E with other foot Figure 5 Testing foot grounding devices with the 41220 PS 2094 Page 3 of 4 Specifications Operating Voltage 100 240 VAC 50 60 Hz Current Drain 20mA Test Voltage Open Circuit 30 VDC Equipment Ground Resistance Limit 1 kilohm Resistance Limits Wrist Strap 750 kilohms to 10 megohms Resistance Limits Foo...

Page 4: ...ystems com factory Warranty replacements will take approximately two weeks Warranty Exclusions THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES EXPRESSED AND IMPLIED INCLUDING MER CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED The express warranty will not apply to defects or damage due to accidents neglect misuse alterations opera...