Safety Instructions

!

When working with CAN-PCI/200 follow the instructions below and read the manual carefully to protect yourself from 
injury and the CAN-PCI/200 from damage.

!

The device is a built-in component. It is essential to ensure that the device is mounted in a way that cannot lead to 
endangering or injury of persons or damage to objects.

!

The device has to be securely installed in the control cabinet before commissioning.

!

Protect the CAN-PCI/200 from dust, moisture and steam. 

!

Protect the CAN-PCI/200 from shocks and vibrations.

!

The CAN-PCI/200 may become warm during normal use. Always allow adequate ventilation around the CAN-PCI/200 
and use care when handling.

!

Do not operate the CAN-PCI/200 adjacent to heat sources and do not expose it to unnecessary thermal radiation. 
Ensure an ambient temperature as specified in the technical data.

!

Do not use damaged or defective cables to connect the CAN-PCI/200 and follow the CAN wiring hints in chapter: 
"Correctly Wiring Electrically Isolated CAN Networks".

!

In case of damages to the device, which might affect safety, appropriate and immediate measures must be taken, that 
exclude an endangerment of persons and objects. 

!

Current circuits which are connected to the device have to be sufficiently protected against hazardous voltage (SELV 
according to EN 60950-1).

!

The CAN-PCI/200 may only be driven by power supply current circuits, that are contact protected. 
A power supply, that provides a safety extra-low voltage (SELV or PELV) according to EN 60950-1, complies with this 
conditions.

Attention !
Electrostatic discharges may cause damage to electronic components. 

To avoid this, please perform the steps described on page 

before

 you touch the CAN-PCI/200, 

in order to discharge the static electricity from your body.

Qualified Personal

This documentation is directed exclusively towards personal qualified in control and automation engineering. 
The installation and commissioning of the product may only be carried out by qualified personal, which is 
authorized to put devices, systems and electric circuits into operation according to the applicable national 
standards of safety engineering.

Conformity

The CAN-PCI/200 is an industrial product and meets the demands of the EU regulations and EMC standards 
printed in the conformity declaration at the end of this manual for the use in industrial environment.

Intended Use

The intended use of the CAN-PCI/200 is the operation as a PCI-CAN interface. 
The   guarantee   given   by   esd   does   not   cover   damages   which   result   from   improper   use,   usage   not   in  
accordance with regulations or disregard of safety instructions and warnings.

!

The CAN-PCI/200 is intended for installation in PCI systems only.

!

The operation of the CAN-PCI/200 in hazardous areas, or areas exposed to potentially explosive 
materials is not permitted.

!

The operation of the CAN-PCI/200 for medical purposes is prohibited.

Service Note

The CAN-PCI/200 does not contain any parts that require maintenance by the user. The CAN-PCI/200 does 
not require any manual configuration of the hardware.

Disposal

Devices which have become defective in the long run have to be disposed in an appropriate way or have to  
be returned to the manufacturer for proper disposal. Please, make a contribution to environmental protection.

Page 4 of 23

Hardware Manual • Doc. No.: C.2021.21 / Rev. 1.1

CAN-PCI/200

Summary of Contents for C.2021.02

Page 1: ...21 Rev 1 1 Page 1 of 23 esd electronic system design gmbh Vahrenwalder Str 207 30165 Hannover Germany http www esd eu Phone 49 0 511 3 72 98 0 Fax 49 0 511 3 72 98 68 esd electronic system design gmbh...

Page 2: ...esd s written approval 2012 esd electronic system design gmbh Hannover esd electronic system design gmbh Vahrenwalder Str 207 30165 Hannover Germany Phone 49 511 372 98 0 Fax 49 511 372 98 68 E Mail i...

Page 3: ...Changes versus previous version Date 1 1 Added new trademarks 2012 04 13 1 1 New safety instructions 2012 03 01 1 1 1 2 New picture of the top layer 2012 03 01 1 1 2 Update chapter Hardware Installat...

Page 4: ...es may cause damage to electronic components To avoid this please perform the steps described on page 8 before you touch the CAN PCI 200 in order to discharge the static electricity from your body Qua...

Page 5: ...ion 13 5 2 Light Industrial Environment Single Twisted Pair Cable 14 5 2 1 General Rules 14 5 2 2 Cabling 15 5 2 3 Termination 15 5 3 Electrical Grounding 16 5 4 Bus Length 16 5 5 Examples for CAN Cab...

Page 6: ...be set by software The CAN interface is electrically isolated from the other potentials by optocouplers and DC DC converters Page 6 of 23 Hardware Manual Doc No C 2021 21 Rev 1 1 CAN PCI 200 5 V 5 V...

Page 7: ...1 2 PCB View with Connectors Figure 2 Top layer view of the module with 2x CAN CAN PCI 200 Hardware Manual Doc No C 2021 21 Rev 1 1 Page 7 of 23...

Page 8: ...on again unintentionally i e with caution label Danger Never carry out work while power supply voltage is switched on 4 Open the case 5 Select an open PCI slot and remove the slot cover at the back o...

Page 9: ...x 119 91 mm PCB only Weight 85 g 1 x CAN 100g 2 x CAN Table 1 General technical data of the module 3 2 PCI Bus Host Bus PCI bus according to PCI Local Bus Specification 2 1 PCI bus width 32 bit Contr...

Page 10: ...plers and DC DC converters DeviceNet Option adapter board with DeviceNet connector in Phoenix Combicon style optocouplers and CAN driver according to DeviceNet specification DeviceNet Communication Mo...

Page 11: ...reserved CAN_GND 6 2 CAN_L CAN_H 7 3 CAN_GND reserved 8 4 reserved reserved 9 5 reserved Signal Description CAN_L CAN_H CAN signal lines CAN_GND reference potential of the local CAN physical layer CA...

Page 12: ...hield to functional earth FE at least at one point 3 The reference potential CAN_GND has to be connected to the functional earth FE at exactly one point 4 A CAN bus line must not branch exception shor...

Page 13: ...le shielded double twisted pair cables 5 1 3 Termination Use external termination plugs because they can later be rediscovered more easily than internal terminations within the CAN devices A 9 pin DSU...

Page 14: ...actly one point 4 A CAN net must not branch exception short cable stubs and has to be terminated with the characteristic impedance of the line generally 120 10 at both ends between the signals CAN_L a...

Page 15: ...with single shielded single twisted pair wires 5 2 3 Termination Use external termination plugs because they can be rediscovered more easily than internal terminations within the CAN devices 9 pin DSU...

Page 16: ...delaying the CAN signals esd modules typically reach a wire length of 37 m at 1 Mbit s within a closed net without impedance disturbances like e g cable stubs 0 3 m Bit rate Kbits s Typical values of...

Page 17: ...ppflex PUR C 1x 2x 0 25 mm Order No 94 025 016 UL appr 5 5 2 Cable for Heavy Industrial Environment Applications Four Wire Manufacturer Cable Type U I LAPP GmbH Schulze Delitzsch Stra e 25 70565 Stutt...

Page 18: ...ors To test it please 1 Turn off all power supplies of the attached CAN nodes 2 Measure the DC resistance between CAN_H and CAN_L at the ends of the network see figure above and at the centre of the n...

Page 19: ...t possibly still be able to transmit data if there is a short circuit between CAN_GND and CAN_L but the error rate will increase strongly Make sure that there is no short circuit between CAN_GND and C...

Page 20: ...ircuits may increase the leakage current in these circuits To measure the current leakage through the CAN circuits please use an resistance measuring device and 1 Switch off the node and disconnect it...

Page 21: ...7 Declaration of Conformity CAN PCI 200 Hardware Manual Doc No C 2021 21 Rev 1 1 Page 21 of 23...

Page 22: ...esd CAN Hardware includes Windows XP object code J1939 Simulation Tool esd CAN Windows driver license C 1130 10 J1939 Stack for Linux J1939 Stack for esd CAN Hardware includes Linux object code esd C...

Page 23: ...le 6 Available manuals Printed Manuals If you need a printout of the manual additionally please contact our sales team sales esd eu for a quotation Printed manuals may be ordered for a fee CAN PCI 200...

Reviews: