7.10.3 Change Polarity Output 8-bit (6202
h
)
This object inverts the relay coil control voltage.
Index
Sub-
index
Description
Value
range
Default
Data type
Access
6202
h
0
number_of_output 8-bit
1
1
unsigned 8
const
1
change polarity output_8-bit
00...0F
h
0
unsigned 8
rw
Assignment of the variable change_polarity_output_DO8-DO1:
This variable determines whether a relay is inverted.
Bit:
7
6
5
4
3
2
1
0
Relay:
-
-
-
-
Rel_4
Rel_3
Rel_2
Rel_1
Bit value Rel_x
Meaning
0
Digital output of rely x is not inverted.
Relay coil x is energized by setting the output bit of object 6200
h
to ‘1’
1
Digital output of rely x is inverted.
Relay coil x is energized by setting the output bit of object 6200
h
to ‘0’