Parameter Display and Configuration via
CICT
CAN-CBM-DP
Software Manual Rev. 2.0
85
Net
Net
indicates the CAN network for which the CANOPEN standard objects from the CANOPEN module
specified under
Module No.
are to be determined. A 0 indicates CAN network 1 and a 1 indicates CAN
network 2. The value can only be changed for CAN interface modules which have more than one CAN
network.
Module No.
Module No.
displays the module No. whose values are to be displayed.
7.2.7.3 Config Modules
Fig. 7.2.16:
Window
Config CANOPEN Modules
Net
Net
indicates the CAN network for which the CANOPEN standard objects from the CANOPEN module
specified under
Module No.
are to be determined. A 0 indicates CAN network 1 and a 1 indicates CAN
network 2. The value can only be changed for CAN interface modules which have more than one CAN
network.
Module No.
Module No.
displays the module No. whose values are to be displayed.
Tx SDO / Rx SDO
TxSDO and RxSDO indicate the transmission or reception CAN identifier for the CANOPEN module
No. specified under
Module No..
Index
Indicates the index of the SDO.
Sub Index
Indicates the sub index of the SDO.
Data
Here the data is entered which is to be written, or the received data is displayed.