Connector Assignments
2.1.3 Usage in Heavy Industrial Environment (
Double
Twisted Pair
Cable)
When using the esd’s CAN-T-Connector type C.1311.03 with single shielded
double
twisted pair
cables in heavy industrial environment applications, please note that the shield potential of the
conductive DSUB housing is not looped through this CAN-T-connector type (see also chapter
“Device Cabling” page 15).
Thus, the braided shields of the CAN cables have to be connected to an external shield
connection, for example via clamp straps (see Figure 5), to connect the shield potentials of the
cables.
Fig. 5:
Internal connection of the CAN-T-Connector using double twisted pair cable
Page 10 of 22
Manual • Doc. No.: C.1311.21 / Rev. 1.3
CAN-T-Connector
CAN_H
CAN_GND
CAN_L
C
A
N
_H
C
A
N
_G
N
D
C
A
N
_L
Braided Shield
Metal Shell
Braided Shield
Metal Shell
Braided Shield
Metal Shell
External shield connection
Connect for example
via clamp strap
for shield connection
Connect for example
via clamp strap
for shield connection
Connect for example
via clamp strap
for shield connection
Optional Earthing
n.c.
n.c.
n.c.
n.c. ... not connected