19.
Group commands 1-Wire actuators
A large number (=> group) of 1-Wire actuators can be controlled with a single function. The advantage is that not
a single command is required for each individual 1-Wire actuator (OWD).
All 1-Wire actuators (OWD´s) included in a group respond to this single command. Previous individual commands
remain completely unaffected by group commands. You can use individual 1-Wire actuators, e.g. control 1-Wire
shutter directly by command and/or by a group command.
Each 1-Wire Actuator (OWD) can be assigned up to 8 group addresses in a range of 1-240.
Double group addresses are automatically filtered out by the 1-Wire Controller / 1-Wire Gateway.
Example of the structure of group commands
Steering 1-Wire shutter with upward travel:
Command: SET,OWD,GRP,SHT,function
After performing a group command, the status of each individual 1-Wire actuator (OWD´s) is reported back as
usual.
All group commands (including short descriptions) can be referred back under the item "Command list / Set One
Wire Device C
ommand, group commands”.
In order to quickly apply group commands, we have included the commands in the command list.
The command list can be found under the tab "DATA/DEBUG" / "COMMAND".
If commands are not listed there, an update of Config-Tool 3 is necessary. The update can be performed under
the "HOME" tab with the "CONFIG TOOL UPDATE" button.
All commands in the command list can be used directly for programming the 1-Wire Controller, 1-Wire Gateway