Art. No. 11308 

Windows:

 

For Windows, a bus coupler configuration program (Config-Tool) and a software for the creation of a virtual serial 
port (VSP-Tool) are available. 
 

Linux:

 

At the moment we have no available configuration software, respectively connection for Linux. 
We would like to refer to the „remserial“ project: 

http://lpccomp.bc.ca/remserial/

.

 

 

Update Ethernet interface (Firmware for interface) 

No firmware update of the Ethernet interface should be necessary during the entire lifetime.   
If you do, please use the "Config Tool 1" of the software package. 
Before starting the update, close all applications and services that could write or read data to the bus coupler! 
Malfunctions of the 1-Wire bus coupler due to programming or an update are not subject to the warranty 
conditions. 
Should an update nevertheless be necessary, we will be pleased to carry out an update for you as a service. We 
are also happy to carry out the programming of the network interface for you. In this case, please return the 
device back to us for further handling. 
  

Connection plan 

 
Module top side  
(1-Wire Bus) 
 

7 + 8     = 1-Wire GND/load 
9 + 10  = 1-Wire data 
11+12  = + 5V output 

 

 
 
Modul bottom side  
(voltage supply) 

1 = Minus input 9-30V 
2 = Plus input 9-30V  
3 - 6 = not in use 
 
 
 
 
 
 
 

Operating conditions 

The operation of the assembly group can take place only on condition of observing the required voltage and the 
ambient conditions. The operating position of the device is irrelevant. The device is meant to be used in dry and 
dust-free areas. 
Should condensed water build up, an acclimatization period of at least 2 hours must pass. 
Assembly groups and components do not belong into the hands of children! 
The building group can be operated only under the supervision of an electrically skilled person. 
In industrial facilities, the accident prevention regulations of the federation of industrial professional associations 
for electrical installations and equipments must be observed. 
Do not operate the assembly group in an environment with inflammable gases, vapours or dusts or in an 
environment where such gases, vapours or dusts may be found. 
 

Summary of Contents for 11308

Page 1: ...ound loops or fault transmissions between 1 Wire network and computer are prevented by the use of the 1 Wire bus coupler Ethernet Within the 1 Wire Bus Coupler the serial to 1 Wire module DS2480 from Dallas Maxim is used This module in combination with the complex internal power supply and the Ethernet module are the basis for a very stable 1 Wire network The 1 wire master within the 1 wire bus co...

Page 2: ...rminals up to 2 5 qmm wire cross section Output voltage 5V 10 nominally 200mA max 300mA Isolation Galvanic separation between Ethernet and 1 Wire interface Ambient conditions Temperature operation 0 C up to 50 C Air humidity 10 92 non condensing Dimensions 35 x 90 x 70mm BxHxD Protection class III Insulation class IP20 Voltage supply Input voltage 8 30VDC Power consumption typically 250mA without ...

Page 3: ... update nevertheless be necessary we will be pleased to carry out an update for you as a service We are also happy to carry out the programming of the network interface for you In this case please return the device back to us for further handling 8 Connection plan Module top side 1 Wire Bus 7 8 1 Wire GND load 9 10 1 Wire data 11 12 5V output Modul bottom side voltage supply 1 Minus input 9 30V 2 ...

Page 4: ...ined generally before the commissioning of a device whether this device or module is basically suitable for the application in which it is to be used In case of doubt consultation with experts or the manufacturer of the components used is absolutely necessary For operational and connection errors outside of our control we assume no liability of any kind for any resulting damage Kits should be retu...

Page 5: ...ding those which are not explicitly marked are trademarks registered trademarks or other copyright or trademarks or titles or legally protected designations of their respective owners and are hereby expressly recognized as such by us The mention of these designations logos names and trademarks is made for identification purposes only and does not represent a claim of any kind on the part of ESERA ...

Reviews: