All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA-Automation or E-Service GmbH. Errors and technical modification subject to change.

©

 ESERA-Automation, E-Service GmbH 2019

 

www.esera.de 

11308 V1.0 R1.0 Manual 

Page 4 of 5

 

 

10 

Assembly 

The module may only be operated at the specified voltages and ambient conditions. The device is 
intended for installation inside a control cabinet as a stationary device. 
 

11 

Disposal note 

Do not dispose of the device within the household waste! 
According  to  the  directive  concerning  old  electrical  and  electronic  appliances,  electronic  devices 
must be disposed of via the collecting points for old electronic 
appliances! 
 
 

12 

Safety instructions 

When using products that come into contact with electrical voltage, the valid VDE regulations must be observed, especially 
VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860 

 

All final or wiring work must be carried out with the power turned off. 

 

Before opening the device, always unplug or make sure that the unit is disconnected from the mains. 

 

Components, modules or devices may only be put into service if they are mounted in a contact proof housing. 
During installation they must not have power applied. 

 

Tools may only be used on devices, components or assemblies when it is certain that the devices are 
disconnected from the power supply and electrical charges stored in the components inside the device have been 
discharged. 

 

Live cables or wires to which the device or an assembly is connected, must always be tested for insulation faults 
or breaks. 

 

If an error is detected in the supply line, the device must be immediately taken out of operation until the faulty 
cable has been replaced. 

 

When using components or modules it is absolutely necessary to comply with the requirements set out in the 
accompanying description specifications for electrical quantities. 

 

If the available description is not clear to the non-commercial end-user what the applicable electrical 
characteristics for a part or assembly are, how to connect an external circuit, which external components or 
additional devices can be connected or which values these external components may have, a qualified electrician 
must be consulted. 

 

It must be examined generally before the commissioning of a device, whether this device or module is basically 
suitable for the application in which it is to be used. 

 

In case of doubt, consultation with experts or the manufacturer of the components used is absolutely necessary. 

 

For operational and connection errors outside of our control, we assume no liability of any kind for any resulting 
damage. 

 

Kits should be returned without their housing when not functional with an exact error description and the 
accompanying instructions. Without an error description it is not possible to repair. For time-consuming assembly 
or disassembly of cases charges will be invoiced. 

 

During installation and handling of components which later have mains potential on their parts, the relevant VDE 
regulations must be observed. 

 

Devices that are to be operated at a voltage greater than 35 VDC / 12mA, may only be connected by a qualified 
electrician and put into operation. 

 

Commissioning may only be realized if the circuit is built into a contact proof housing. 

 

If measurements with an open housing are unavoidable, for safety reasons an isolating transformer must be 
installed upstream or a suitable power supply can be used.  

 

After installing the required tests according to BGV A3 / Betriebssicherheitsverordnung must be performed. 

 

13 

Warranty

 

ESERA-Automation (E-SERVICE GmbH) guarantees that the goods sold at the time of transfer of risk to be free from 
material and workmanship defects and have the contractually assured characteristics. The statutory warranty period of two 
years begins from date of invoice. The warranty does not extend to the normal operational wear and normal wear and tear. 
Customer claims for damages, for example, for non-performance, fault in contracting, breach of secondary contractual 
obligations, consequential damages, damages resulting from unauthorized usage and other legal grounds are excluded. 
Excepting to this, ESERA-Automation accepts liability for the absence of a guaranteed quality resulting from intent or gross 
negligence. Claims made under the Product Liability Act are not affected. 
 
If defects occur for which the ESERA-Automation is responsible, and in the case of replacement goods, the replacement is 
faulty, the buyer has the right to have the original purchase price refunded or a reduction of the purchase price. ESERA-
Automation accepts liability neither for the constant and uninterrupted availability of the ESERA-Automation or for technical 
or electronic errors in the online offer. 
  

Summary of Contents for 11308

Page 1: ...ound loops or fault transmissions between 1 Wire network and computer are prevented by the use of the 1 Wire bus coupler Ethernet Within the 1 Wire Bus Coupler the serial to 1 Wire module DS2480 from Dallas Maxim is used This module in combination with the complex internal power supply and the Ethernet module are the basis for a very stable 1 Wire network The 1 wire master within the 1 wire bus co...

Page 2: ...rminals up to 2 5 qmm wire cross section Output voltage 5V 10 nominally 200mA max 300mA Isolation Galvanic separation between Ethernet and 1 Wire interface Ambient conditions Temperature operation 0 C up to 50 C Air humidity 10 92 non condensing Dimensions 35 x 90 x 70mm BxHxD Protection class III Insulation class IP20 Voltage supply Input voltage 8 30VDC Power consumption typically 250mA without ...

Page 3: ... update nevertheless be necessary we will be pleased to carry out an update for you as a service We are also happy to carry out the programming of the network interface for you In this case please return the device back to us for further handling 8 Connection plan Module top side 1 Wire Bus 7 8 1 Wire GND load 9 10 1 Wire data 11 12 5V output Modul bottom side voltage supply 1 Minus input 9 30V 2 ...

Page 4: ...ined generally before the commissioning of a device whether this device or module is basically suitable for the application in which it is to be used In case of doubt consultation with experts or the manufacturer of the components used is absolutely necessary For operational and connection errors outside of our control we assume no liability of any kind for any resulting damage Kits should be retu...

Page 5: ...ding those which are not explicitly marked are trademarks registered trademarks or other copyright or trademarks or titles or legally protected designations of their respective owners and are hereby expressly recognized as such by us The mention of these designations logos names and trademarks is made for identification purposes only and does not represent a claim of any kind on the part of ESERA ...