10 

 Disposal note 

Do not dispose of the device within the household waste! 
According to the directive concerning old electrical and electronic appliances, 
electronic devices must be disposed of via the collecting points for old electronic 
appliances! 
 

11 

Safety instructions 

When using products that come into contact with electrical voltage, the valid VDE regulations must be 
observed, especially VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860 

 

All final or wiring work must be carried out with the power turned off. 

 

Before opening the device, always unplug or make sure that the unit is disconnected from the mains. 

 

Components, modules or devices may only be put into service if they are mounted in a contact proof housing. 
During installation they must not have power applied. 

 

Tools may only be used on devices, components or assemblies when it is certain that the devices are disconnected 
from the power supply and electrical charges stored in the components inside the device have been discharged. 

 

Live cables or wires to which the device or an assembly is connected, must always be tested for insulation faults or 
breaks. 

 

If an error is detected in the supply line, the device must be immediately taken out of operation until the faulty cable 
has been replaced. 

 

When using components or modules it is absolutely necessary to comply with the requirements set out in the 
accompanying description specifications for electrical quantities. 

 

If the available description is not clear to the non-commercial end-user what the applicable electrical characteristics 
for a part or assembly are, how to connect an external circuit, which external components or additional devices can 
be connected or which values these external components may have, a qualified electrician must be consulted. 

 

It must be examined generally before the commissioning of a device, whether this device or module is basically 
suitable for the application in which it is to be used. 

 

In case of doubt, consultation with experts or the manufacturer of the components used is absolutely necessary. 

 

For operational and connection errors outside of our control, we assume no liability of any kind for any resulting 
damage. 

 

Kits should be returned without their housing when not functional with an exact error description and the 
accompanying instructions. Without an error description it is not possible to repair. For time-consuming assembly or 
disassembly of cases charges will be invoiced. 

 

During installation and handling of components which later have mains potential on their parts, the relevant VDE 
regulations must be observed. 

 

Devices that are to be operated at a voltage greater than 35 VDC / 12mA, may only be connected by a qualified 
electrician and put into operation. 

 

Commissioning may only be realized if the circuit is built into a contact proof housing. 

 

If measurements with an open housing are unavoidable, for safety reasons an isolating transformer must be 
installed upstream or a suitable power supply can be used.  

 

After installing the required tests according to DGUV / regulation 3 (German statutory accident insurance, 

https://en.wikipedia.org/wiki/German_Statutory_Accident_Insurance

must be carried out. 

 

12 

Warranty 

ESERA GmbH guarantees that the goods sold at the time of transfer of risk to be free from material and workmanship defects 
and have the contractually assured characteristics. The statutory warranty period of two years begins from date of invoice. 
The warranty does not extend to the normal operational wear and normal wear and tear. Customer claims for damages, for 
example, for non-performance, fault in contracting, breach of secondary contractual obligations, consequential damages, 
damages resulting from unauthorized usage and other legal grounds are excluded. Excepting to this, ESERA GmbH accepts 
liability for the absence of a guaranteed quality resulting from intent or gross negligence. Claims made under the Product 
Liability Act are not affected. 
If defects occur for which the ESERA GmbH is responsible, and in the case of replacement goods, the replacement is faulty, 
the buyer has the right to have the original purchase price refunded or a reduction of the purchase price. 
ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for technical or 
electronic errors in the online offer. 
We are constantly developing our products further and reserve the right to make changes and improvements to any of the 
products described in this documentation without prior notice. Should you require documents or information on older 
versions, please contact us by e-mail at 

info@esera.de

 

 

 
 
 

Summary of Contents for Auto-E-Connect 11118

Page 1: ...is connected to the 1 Wire network via screw terminals and to the temperature sensor via RJ12 modular jack It is not necessary to remove the existing connectors of the temperature sensor as the pin assignment of the temperature sensors is matched to the 1 Wire Adapter 1 As further system components for the 1 Wire network we recommend the use of a 1 Wire Hub II as power supply and 1 Wire Bus Couple...

Page 2: ... 7 Assignment Screw terminal 1 Wire network Screw terminals 5V 1 Wire Data and GND are provided for connection to the 1 Wire network The assignment is printed on the printed circuit board 8 Operating conditions The module may only be operated at the voltages and ambient conditions specified for it The device can be operated in any position The device is intended for use in dry and dust free rooms ...

Page 3: ...or operational and connection errors outside of our control we assume no liability of any kind for any resulting damage Kits should be returned without their housing when not functional with an exact error description and the accompanying instructions Without an error description it is not possible to repair For time consuming assembly or disassembly of cases charges will be invoiced During instal...

Page 4: ...ed designations of their respective owners and are hereby expressly recognized as such by us The mention of these designations logos names and trademarks is made for identification purposes only and does not represent a claim of any kind on the part of ESERA GmbH on these designations logos names and trademarks Moreover from their appearance on ESERA GmbH webpages it cannot be concluded that desig...

Reviews: