 gas detectors – URD40SE 

16/06/2017 

Gas detection systems for industrial environments 

2/4

 

 

Technical 
characteristics 

 

Type of sensor

 

NDIR (Non Dispersive Infrared) 

Detectable Gas 

Carbon dioxide (CO

2

Power supply 

11÷14Vdc 

Max power consumption 

1,6W 

Measuring range  

0...20,000 ppm 

Precision 

 5% full scale, 

 10% readout 

Repeatability 

 5% full scale, 

 10% readout 

Measurement resolution 

20 ppm 

Microprocessor resolution 

1024 points (10 bit) 

Digital filter system 

Kalman Filter 

Watchdog 

Internal 

Warm-up time 

< 2m 

Stabilization time 

< 2m 

Response time 

< 25s (T90) 

Average Sensor life (in air) 

255 weeks 

Threshold limit settings  
(default setting): 

Pre-alarm 

1

st

 threshold alarm 

2

nd

 threshold alarm 

 
 
2000 ppm

 

4000 ppm 
8000 ppm 
 

Operating Temperature 
Storage Temperature

 

-20 

 50 °C 

-20 

 70 °C

 

Relative Humidity 

(without condensing) 

-

 

Operation 

-

 

Storage

 

 

15 

 90 %RH 

45 

 75 %RH

 

Operating pressure (KPa) 

80 

 110 

Air speed (m/s) 

 6 

Visual warnings 

Red LED visible with detector energized 
The  steady  LED  status  can  be  forced  by 
the  Control  Unit  to  identify  the  sensor  on 
the plant 

Dimensions and weight 

See dedicated section 

Options & Accessories 

 

TUL40..

 Gas calibration kit 

See installation and commissioning chapter

 

TUS40   

Handheld terminal   

for service and maintenance  

See installation and commissioning chapter 

CRG40

   Gas collecting cone 

See dedicated data sheet 

PAP40

   Powerful jets protection 

See dedicated data sheet 

 

 

ATEX markings 

 

 

1370

   

 II 2G   Ex d IIC T6 

 

BVI 07 ATEX 0032 

 

-20°C 

 T

A

 

 +50°C

 

Key to marking 
information

 

 

Marking in conformity with all applicable EC Directives 

1370 

Identification number of Notified Body involved in production control 

 

CE marking for all equipment in conformity with Directive ATEX 2014/34/EC 

II

 

Equipment group for surface industry 

Equipment category 2 for use in Zone 1 

Equipment intended for use in explosive gas atmosphere, caused by mixture of air 
and gas, vapours, flammable mist

 

Ex d IIC T6 

Type of protection complying with EN60079-0 and EN60079-1

 

BVI 07 ATEX 0032  EC-type examination certificate 
-20°C 

 TA 

 +50°C  Operating temperature range 

Sensors  

lifetime 

Sensor  average  lifetime  (see  technical  characteristics)  is  referred  to  a  typical  usage  in  a 
pollution-free  environment.  Presence  of  a  high  concentration  of  pollutants  can  shorten  the 
lifetime of the sensing element. 

Once the detection system starts up, it has to be supplied with energy during all the lifetime 
of its sensors. Seasonal use of the detection system is not recommended.

 