background image

 

23 

 

PARTS LIST (CONTINUED) 

 

ITEM No.  PARTS No. 

DESCRIPTION 

 

DVEL 8 

DVEL 12 

DVEL 20 

 

35 

02220702 

02220705 

Ignitor rod 

36 

01140701D 

Control Knob 

37 

02100117E 

Control panel  

38 

01140908C 

Ignitor button 

39 

012123B 

01212301 

Knob rod 

40 

--- 

01210603 

Adapter 

41 

--- 

010003 

Washer  

42 

05096 

05097 

Gas control valve bracket 

43 

--- 

01190403 

Bolt 

44 

01210408G 
01210404G

 

05269 
05268 

05364 
05363 

Gas control Valve Natural Gas 
Gas control Valve L.P.G. 

45 

05137 

05257 

05376 

Top Radiation Shield 

46 

--- 

01160902 

Nipple 1/4 BSP x 3/8 NPT 

47 

02830110B 

02830138B 

02830140 

Burner tubing 

48 

02830109B 

02830137B 

02830141B  Pilot tubing 

49 

--- 

011935A 

Nut 

50 

01024001 

02830139A 

Gas main inlet tubing 

51 

05087 

05240 

Radiation shield 

52 

01052001 
01052002 

-- 

-- 

Pressure Regulator Natural Gas 
Pressure Regulator L.P.Gas 

53 

01160901 

-- 

-- 

Pressure Tap Fitting 

54 

-- 

-- 

05355 

Front radiation shield 

55 

01143302 

02330101 

Spark plug 

56 

01143127 
01143306 

01080406 
01080405 

Pilot burner orifice Natural Gas 
Pilot burner orifice LPG 

57 

05100 - 

05101 

--- 

--- 

Pressure regulator bracket 

58 

05066 

05201 

05246 

Silicon-rubber ring 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for DVEL 12

Page 1: ...SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareils Ne touchez aucun interrupteur Ne pas vous servir des t l phones dans le b timent o vous vous trouvez Appelez imm diatement votre fou...

Page 2: ...personal injury or loss of life Refer to this manual Installation and service must be performed by a qualified installer service agency or the gas supplier Do not use this appliance if any part has b...

Page 3: ...tion at elevation above 2000 feet 609 9 m manufactured to specified deration conditions for Canada and the United States NOTE Minimum Gas Inlet Pressure for purpose of input adjustment The efficiency...

Page 4: ...ff valve n Ground joint union n Test gauge connection n Sediment trap n Tee joint n Pipe wrench The installation location shall provide the following a adequate combustion and ventilation air and b ad...

Page 5: ...in a horizontal distance of 2 feet 61 cm from the center line of the terminal D 12 inches 30 cm 1 2 M Clearance to unventilated soffit E Clearance to outside corner F Clearance to inside corner G To e...

Page 6: ...and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same room as the appliance Clothing or other flammable material should not...

Page 7: ...HE HANGING BRACKET ON A WOODEN WALL 1 Taking into account the minimum clearances mentioned in figure 4 locate the closest wall stud which will serve to hold the appliance and mark the hole center at a...

Page 8: ...ging bracket and drill the four holes 6 Insert in each hole the anchors provided 7 Place back the hanging bracket and fix it with four screws MOUNTING THE HEATER ON HANGING BRACKET Place the heater on...

Page 9: ...ppareil sont utilis es CAUTION ALL JOINTS MUST BE AIR TIGHT The venting system consists of one injected aluminum cap A one vent pipe B one vent air intake pipe C one rod D one nut E one outdoor mounti...

Page 10: ...nsor from any damage during shipping or while handling it before it is definitely installed the thermostat sensor has not been attached to its final location in the appliance So once the heater is ins...

Page 11: ...uge connections upstream of the gas supply connection to the heater Figure 21 WARNING For L P Gas use PRESSURE REGULATED gas supply Do not directly connect LP supply tank to the pressure regulator on...

Page 12: ...excess of psi 3 5 kPa The appliance must be isolated from the gas supply piping system by closing equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures...

Page 13: ...12 OPERATION CONTINUED Pilot Burner...

Page 14: ...13 POUR COUPER L ADMISION DE GAZ DE L APPAREIL Veilleuse ALLUMAGE...

Page 15: ...from the manufacturing process It is recommended to burn a new wall furnace for at least two 2 hours the first time that it is used CLEANING AND MAINTENANCE WARNING Turn off heater and let cool before...

Page 16: ...attern top view Models DVEL 8 and 12 SECONDARY FLAME PRIMARY FLAME THERMOCOUPLE PILOT FLAME Fig 26 Correct main burner flame pattern top view Model DVEL 20 Cleaning the Main Burner Orifice and Main Bu...

Page 17: ...hen installed 4 Continue holding down control knob Repeat igniting operation until air is removed 5 Pilot is clogged 5 Clean pilot orifice or replace pilot assembly When ignitor button is pressed ther...

Page 18: ...ses 1 Problem will stop after a while of operation 1 Turning control knob to HI position when burner is cold 1 Turn control knob to LO position and let warm up for a minute 2 Air in gas line 2 Operate...

Page 19: ...ements parts must be returned the authorized distributor A UNDER WARRANTY Contact authorized dealers of this product If they are unable to supply original replacement part s call the authorized distri...

Page 20: ...19 Model DVEL 8 19...

Page 21: ...Model DVEL 12 20...

Page 22: ...Model DVEL 20 21...

Page 23: ...Sensor bracket 18 05078 Knob support 19 01021307 Elbow 3 8 NPT x 3 8 NPT 20 01021301 Elbow 1 4 BSP x 1 4 BSP 21 05083 05228 05334 Bracket 22 01082001 01081403 02230113 01082102 01082002 01081403 Burne...

Page 24: ...5 05137 05257 05376 Top Radiation Shield 46 01160902 Nipple 1 4 BSP x 3 8 NPT 47 02830110B 02830138B 02830140 Burner tubing 48 02830109B 02830137B 02830141B Pilot tubing 49 011935A Nut 50 01024001 028...

Page 25: ...24 ESKABE S A Ruta 2 No 323 7600 Mar del Plata Pcia de Buenos Aires Argentina Authorized Distributor in USA and Canada Cod Mat XXXX XX XXX...

Reviews: