18
Kongsberg C-series
A fault code will be displayed in the event that either the Vertical or Horizontal servos become
faulted.
The fault code can be looked up in the “Kollmorgen AKD PDMM Fault Card EN Rev F.pdf”
document that is provided with the machine on the documentation thumb drive.
9 - Jog Functions Screen
The Jog Functions screen allows the operator to enable jogging of the vertical carriage beam
UP/Down and the horizontal Gantry Forward/Reverse using the Jog selector switch on the
control console.
The machine Mode selector switch must be set to Manual in to enable the jog features.
When enabled, the round circle associated with the screen button will be green.
Switching back to Auto mode automatically cancels the enabled Jog Functions.
18.11. Starting Up the i-BF for Daily Operation
The i-BF can be powered OFF when not in use by pressing the red Power OFF pushbutton
located on the door of the electrical enclosure, and/or by switching off the main power
disconnect.
Main Disconnect Power ON
To start up the i-BF; set the Main Disconnect
to the ON position, and then press the lighted
Power ON pushbutton located on the door of
the electrical enclosure.
Once pressed, the white lighted pushbutton
will be turned on, indicating that control
power has been applied to the system.
The i-BF control system requires a short
period of time to initialize.
206