19
Kongsberg C-series
19.5. Power On/Off Controls
Main Power Disconnect and Power On/Off Controls
Main Disconnect switch
The picture shows the Main Disconnect switch
in the 1 or ON position.
The Main Disconnect switch is located on the
door of the electrical enclosure.
Switching to the 1 or ON position connects the
high voltage input power to the i-BF electrical
system.
The disconnect mechanically prevents the electrical enclosure door from opening when the
switch is in the 1 position.
Power is removed from the system when the disconnect is in the 0 position.
In the 0 or OFF position the enclosure door is allowed to open.
WARNING
Never operate the i-BF with the electrical enclosure door open and the disconnect manually
switched to the ON position.
High voltage is also present within the enclosure even with the disconnect in the OFF position.
The i-BF electrical system should only be serviced by qualified experienced technicians.
Power ON / OFF Pushbuttons
The Power ON / OFF pushbuttons are located
on the door of the electrical enclosure.
Power ON pushbutton
Pressing the white Power ON pushbutton will
turn control power on to the i-BF.
Power ON is indicated by the white Power ON
pushbutton illuminating.
Power OFF Pushbutton
Pushing the Power OFF pushbutton will cause the i-BF control power to be turned off.
The machine will not operate in any mode when control power is off.
227