19
Kongsberg C-series
- The
Board Feeder
is equipped with 3
Emergency Stop
buttons.
Here are the rules and prerequisites for how to operate:
Initial Startup, complete system
No
Emergency Stop
buttons are activated.
Press
Safety Reset
on
Cutting Table
.
Both
Cutting Table
and
Board Feeder
safety will be reset.
Run Cutting Table only
Power on
Board Feeder
can be off.
No
Emergency Stop
buttons on
Board Feeder
are activated.
When any Emergency Stop is activated
Both
Cutting Table
and
Board Feeder
will perform an emergency stop.
Remove the root cause for the emergency situation.
Reset the
Emergency Stop
button activated.
Power up the system.
Press
Safety Reset
on
Cutting Table
.
Other safety issues on the Cutting Table
The
Cutting Table
safety system will be triggered.
Ensure the faulty situation is removed.
Press
Safety Reset
on
Cutting Table
to continue.
Other safety issues on the Board Feeder
The
Board Feeder
safety system will be triggered.
Ensure the faulty situation is removed.
Press
Safety Reset
on
Board Feeder
to continue.