12
Kongsberg XL
During normal operation, the cooling medium temperature is displayed.
If any chiller failure occurs:
• Alarm signal is generated.
• Chiller will stop.
• Look at the chiller display to see the real reason for the problem:
Code
Description
AL
Water level or water flow too low. Check for correct water level in the
Water Level Indicator on Chiller front.
H1 (Chiller 2016)
Temperature of cooling medium too high, > 35
o
C / 95
o
F
H1 (Chiller 2020)
Temperature of cooling medium too high, > 45
o
C / 95
o
F
L1
Temperature of cooling medium too low, < 19
o
C / 66
o
F
Continue after error situation
• Find root cause for the error situation and fix it. Flow too low is normally caused by a
squeezed water hose.
• Switch chiller unit OFF and ON again.
More information is available from the Operating instructions for the chiller.
12.11.
Measuring Foot
The
Measuring Foot
has 3 functions:
1.
Measure the thickness of the material on
the table.
2.
Map table top surface.
3.
Measure the cutting underlay top level,
used as reference for tool height control.
In addition:
1.
The foot keeps material down during
operation.
2.
The foot keeps the material down when the
knife blade is pulled out.
No adjustments are necessary.
108