5
Kongsberg XN / iPC 2.0
20
Note:
Activating the
Emergency Stop Button
does not provide a guarantee against injury!
Due to the high kinetic energy of moving parts, do not underestimate
Stop Distance
of
traverse, Y carriage and
Tool Head
.
5.7.3 Warning Lamp on top of Y Carriage
Light is
Description
Off
Servo Power
is off
On
Servo Power
is on,
Safety System
is enabled, table is in operation
Flashing
Safety System
is activated.
Reset
Safety System
to continue operation
5.7.4 DynaGuard Safety System
The
DynaGuard Safety System
consists of two light beams in front of the traverse and one
behind.
In addition, there is a stop mechanism mounted on each end of the traverse.
Machine movement will stop and
Servo Power
will be switched off if:
• One of the light beams are broken.
• The stop mechanism is activated, for instance when a person is standing too near the table.
Continue after DynaGuard is triggered
To continue operation, proceed as follows:
1.
Ensure the table is free from obstructions and ready for operation.
2.
Reset the
Safety System
by pressing the
Pause
pushbutton.