background image

Operating manual 

battery station 12 V/ 7 Ah, 12 V/ 12 Ah

These instructions relate ONLY to this product and contain important 

information for using the product for the first time. Please keep these 

instructions for later reference and should always accompany the product 

in the event of transference to a new user.

1. Introduction

Dear Costumer, thank you for purchasing the solar pump kit. 

With this solar pump kit you purchased a product manufactured according to 

the current state of technology. 

This product fulfils all requirements of the valid European and natio-

nal regulations. The conformity was proved. The relevant declarations 

and documentation are deposited with the manufacturer. 

To maintain this state and guarantee a safe operation, you as the user will have 

to follow this operating manual!

2. Safety Instructions

  

- In case of damages caused by not following 

  

  this operating manual, the warranty rights 

 

  will expire! We exclude liability for any 

 

  consequential damages!

 

- We exclude liability for property or 

 

  personal damages caused by inappropriate

  

  handling or not following the safety instructions. 

 

 

- In these cases any guarantee rights will expire.

Due to safety and admission reasons (CE) it is not allowed to arbitrarily recon-

struct and/or change the solar pump kit. 

Therefore, please keep to the operating manual. 

The accident prevention rules of the association of the industrial trade coope-

rative association for electric plants and working material are to be considered 

in industrial environments

3. Intended Use

-   The accumulator station is universally usable for the energy supply of 

pumps and other products.  

-   The accumulator station has 2 switchable outputs with different voltages.

-  Output 1 has an output voltage of 18 VDC. A timer function may be 

activated.

-  Output 2 has an output voltage of 6 VDC. 

-   The accumulator station is switched off and on via a switch. The 

accumulator is further charged in a switched off state.  

-  The installed accumulator is protected against total discharge, 

overcharging and short circuit.

-   LEDs provide information about the state of charge and the charge of 

the accumulator as well as about the status of the outputs.  

-   The system is ready-to-plug-in and set up in a matter of minutes.  

Note: The accumulator station must not be set up in the blazing sun or in 

the water.  It is designed in IP 44 (splashproof).

Mode of operation of the accumulator station:

The accumulator station is interconnected between (a) solar module(s) and 

the corresponding devices. 

>> For initial start, please first connect the battery. 

See separate instructions! <<

In the sun, the solar module generates electrical energy and charges the 

installed accumulator. The connected consumers are switched on as soon 

as the accumulator voltage is in an operational range. The LED „SYSTEM“ 

provides information about the state of charge of the accumulator. 

green light means:    accumulator is ready for operation!

red light means:        accumulator is exhausted and switched off

The electronics protects the accumulator against total discharge, 

overcharging or short circuit. 

The charging of the accumulator always has priority over the 

operation of the consumers. 

4. Assembly and Start-up

4.1 Connection of the solar module

A maximum of 50 Wp of solar module capacity 

may be connected to the accumulator box. 

The solar module is connected at the cable 

on the back side of the accumulator box. A 5m 

extension cable for this cable is included in the 

set.  

Depending on the version, you may connect one or several solar modules to 

the accumulator station. A single solar module may directly be connected to the 

accumulator box with the plug. A Y-distributor is required if you intend to connect 

2 solar modules (e.g. 2 pieces 25 Wp).  Via the Y-distributor, both solar modules 

are joined and then connected to the accumulator station.  

If required, the cable may be extended by another 5 m extension cable. 

As soon as the solar module is connected and sunlight falls onto the solar 

module, the LED  „Charging“ will light up . The accumulator is fully charged 

if the LED is flashing.

Please note that the solar modules are positioned shadow-free directed towards 

the south and that they are mounted in a stable way.

Attention: The electronics in the accumulator box will be destroyed if more than 

50 W of solar module capacity is connected!

4.2 Main switch „SYSTEM“

The toggle switch „SYSTEM  ON/OFF“  is 

applied at the front side of the accumulator 

box. The outputs are switched off if this 

switch is switched off („OFF“), however, the 

accumulator is still charged. In position „ON“, 

the LED „SYSTEM“ shines red or green. 

When the LED shines green, then the 

accumulator is charged sufficiently and the outputs may be operated as required 

via the buttons on the lid of the box. When the LED shines red, then the outputs 

are switched off and the accumulator has to be charged until the LED shines 

green (see item 6)

4.3 Connecting the consumers

The accumulator box has 2 outputs. Those 

may be switched on or off via the „ON/OFF“ 

button. The green LED above the button 

shines green when the output is active. 

All outputs are protected against short 

circuit. In case of a short circuit in output 1, 

the green LED of the output will additionally flash until the fault is eliminated. 

Below, every output is described individually. Output 2 is equipped with a 

protective cap. This cap has to be removed before connecting consumers. 

!

GB

Customer support:

  If you have problems or questions regarding this product, simply contact us!  

  Monday to Friday 8 am to 12 noon and 1 pm to 4 pm.

  By phone: +49 9605-92206-0

  By e-mail for ordering spare parts: ersatzteil@esotec.de

  By e-mail for questions about the product: technik@esotec.de

  Product: Manufacturer Item No.: 101812, 101816

Y - Adapter

Reviews: