Important assembling advice: Easy Drain

®

Suitable for renovation work and new construction

Typing and printing errors reserved. Easy Sanitary Solutions BV excludes all liability for any damages whatsoever associated with the use and/or 

the installation of the shower drain. Easy Sanitary Solutions BV a priori excludes any liability whatsoever.

The shower drain should only be installed by specialist companies in compliance with the building 

regulations. To achieve the best possible result, please carefully read the installation guide. If you have 

any questions, please consult your supplier.

USA

 

Please check the content of the package for 

completeness and integrity before proceeding with 

the assembly. Do not install the drain if any deviations 

are noted. Should this be the case, please consult your 

supplier.

 

Prior to construction, the installation procedure and its 

special considerations should be discussed with the tile 

setter.  After the installation of the drain body (rough) 

is complete, please provide the tile setter with the 

complete installation guide.

 

If the drain is used for large showers with multiple heads, 

please check to make sure that the drainage capacity is 

sufficient. If you are unsure, please consult the supplier 

for advice.

 

If you do not wish to use the second drainage level 

(secondary water drainage), the joint between the 

shower drain body and the TAF (tile frame) should be 

sealed with a permanent sealer. 

 

We recommend taping or closing the drain opening 

of the shower drain with a cement cap prior to the 

assembly to prevent construction debris from getting 

into the drainage pipe. To prevent damage to the TAF 

(tile frame), it should be kept in the package until the final 

installation by the tiler.

 

Make sure the drain is level all around. 

 

Install the sewage system in compliance with the local 

and national codes.

 Note: 

ensure that the sewage 

system is properly vented and correctly pitched. 

 

Check the drainage system and the sewer system 

connection for water tightness. 

 

In order to prevent hollow spaces, all empty space 

beneath the drain must be completely filled up and 

sealed with floor pavement up to the top edge of the 

drain flange.

 

The seal must be in compliance with the state and local 

standards.

 

When tiles are being fitted, the pitch of the tiles (min. 

2% per 3’3” (≈1m

1

)) in the shower must always be sloped 

towards the drain. The tiles should be laid level or 3/64”  

(≈1 mm) higher than the top edge of the tile frame to 

ensure good drainage toward the shower drain.  

 

Note:

 the requirements with regard to the floor 

gradient may be different for walk-in showers with glass 

walls. Please consult your supplier in this respect.

 

Once the tiles have been fitted, the joint between the 

tiled floor and the TAF (tile frame) should be permanently 

sealed with an elastic sealant (maintenance joint). The 

adhesion surfaces should be free of mortar, adhesive and 

other adhesion-reducing materials. 

 

The drain is only intended for use with waste water 

common in households. Do not use other fluids as well 

as cleaning agents with the potential to damage sanitary 

equipment, drainage equipment and raw materials.

 

If the drain is used for other purposes (e.g. swimming 

pools), where it may come in contact with aggressive 

cleaning agents or corrosive substances such as salt or 

chlorine, please consult your supplier.

 

Construct the floor according to state and local building 

codes.

 

Compliance with this installation advice is required for 

any warranty claims. Deviation from the installation 

instructions will void the warranty.

Caution !

 

Tile cleaning products often contain aggressive 

chemicals that are abrasive in nature and may damage 

the drain. Please ensure that the drain is thoroughly 

flushed after using any tile and grout cleaning products.

 

10 Years limited warranty only applies when constructed 

according to all installation instructions.

 

Glass gratings are not suited for wheelchair accessibility. 

MAINTENANCE INSTRUCTIONS

 

Do not use abrasives and/or sharp/scraping objects to 

clean the Easy Drain

®

 

The hair catcher should be cleaned periodically to 

remove any dirt that may have collected.

 

We recommend the use of Easy CLEANSET for daily 

maintenance and cleaning of your Easy Drain

®

.

Summary of Contents for Easy Drain M-line

Page 1: ...INSTALLATION MANUAL Installation manual Consejo para la instalación Conseils de montage USA ES FR M line FOR CONCRETE AND WOODEN FLOORS M line ...

Page 2: ...2 M line Installation options 3 Installation guide 4 Sealing advice 15 Cleaning 21 Important assembling advice 22 M1 M4 CONTENTS Contenido Table des matières ...

Page 3: ...63 mm 7 18 mm A 40 mm 252 mm 48 mm 20 mm Ø2 5 1 8 2 3 50 8 mm 89 mm 70 mm 131 mm A 1 5 8 A 3 WPS Water Protection System 1 14 mm 33 mm 83 mm 7 18 mm A 40 mm 20 mm 89 mm 70 mm 3 2 2 Ø50 mm 1 9 16 39 mm 2 Ø2 Ø50 mm M1 M4 INSTALLATION OPTIONS Opciones de instalación Variantes de montage ...

Page 4: ...ERTIGHT THE TOP OF THE CLAMP DRAIN MUST BE INSTALLED AT LEAST ABOVE THE WOODEN FLOOR 6 PAN LINER WITH ADHESIVE BONDING 7 8 SEAL THE ENTIRE FLOOR WITH PAN LINER REMOVE AIR POCKETS BENEATH THE LINER CONCRETE BOARD AT LEAST ABOVE THE FLOOR SLOPED MORTAR BED CLAMP DRAIN NOT INCLUDED INSTALLATION GUIDE CLAMP DRAIN VERTICAL OUTLET M4 Manual de instalación Explications de montage ...

Page 5: ...5 M line DO NOT PIERCE ANY WATERPROOFING LINER 12 13 14 11 10 15 9 OPTION CURBLESS SHOWER INSTALLATION 16 ...

Page 6: ...6 M line 18 17 ELECTRICAL GROUNDING CLIP 19 TEST WATERTIGHTNESS CONTINUE WITH IMAGE 1 ON PAGE 11 ...

Page 7: ...ADHESIVE BONDING OVER THE FIRST SLOPED MORTAR LAYER SEAL THE ENTIRE FLOOR WITH PAN LINER REMOVE AIR POCKETS BENEATH THE LINER CONCRETE BOARD AT LEAST ABOVE THE FLOOR OPTION CURBLESS SHOWER INSTALLATION NO HUB SLEEVE NOT INCLUDED INSTALLATION GUIDE NO HUB SLEEVE VERTICAL OUTLET M4 Manual de instalación Explications de montage ...

Page 8: ...8 M line 10 9 ELECTRICAL GROUNDING CLIP TEST WATERTIGHTNESS 11 CONTINUE WITH IMAGE 1 ON PAGE 11 ...

Page 9: ...AL THE ENTIRE FLOOR WITH PAN LINER REMOVE AIR POCKETS BENEATH THE LINER CONCRETE BOARD AT LEAST ABOVE THE FLOOR ELECTRICAL GROUNDING CLIP DO NOT PIERCE ANY WATERPROOFING LINER INSTALLATION GUIDE HORIZONTAL OUTLET M1 Manual de instalación Explications de montage ...

Page 10: ...10 M line 9 10 NO HUB SLEEVE TEST WATERTIGHTNESS CONTINUE WITH IMAGE 1 ON PAGE 11 ...

Page 11: ...BED 2 SLOPE 1 A B A B FILL UP ALL HOLLOW SPACES BENEATH THE DRAIN FILL UP ALL HOLLOW SPACES BENEATH THE DRAIN 4 5 6 SEALING COMPOUND Easy2Seal Easy2Seal 2K SEALING COMPOUND Easy2Seal Easy2Seal 2K INSTALLATION GUIDE Manual de instalación Explications de montage ...

Page 12: ...12 M line 7 11 10 8 9 11 12 12 SEALING COMPOUND Easy2Seal Easy2Seal 2K OPTIONAL WET AREA WATER PROTECTION SET MAX TILE THICKNESS 3 4 18 mm A B A B ...

Page 13: ...LEABLE GRATE 1 2 DEPTH 12 mm 13 17 16 14 15 17 SEALING ADVICE PAGE 15 Easy Silicon EDSIL 1 Easy Compound ED2C 18 19 OPTIONAL SEALING ADVICE PAGE 15 Easy Silicon EDSIL 1 Easy Compound ED2C NO SECONDARY DRAINAGE B A ...

Page 14: ...14 M line 20 ...

Page 15: ...15 M line ONLY PRIMARY DRAINAGE Sólo desagüe de agua primario Seule évacuation primaire SEALING ADVICE CLAMP DRAIN VERTICAL OUTLET M4 Consejo de sellado Conseil pour étanchéifier ...

Page 16: ...16 M line Only apply with waterproofing of the entire shower floor WITH SECONDARY UNDERTILE DRAINAGE Con desagüe de agua secundario Avec évacuation secondairee ...

Page 17: ...17 M line ONLY PRIMARY DRAINAGE Sólo desagüe de agua primario Seule évacuation primaire SEALING ADVICE NO HUB SLEEVE VERTICAL OUTLET M4 Consejo de sellado Conseil pour étanchéifier ...

Page 18: ...18 M line Only apply with waterproofing of the entire shower floor WITH SECONDARY UNDERTILE DRAINAGE Con desagüe de agua secundario Avec évacuation secondairee ...

Page 19: ...19 M line ONLY PRIMARY DRAINAGE Sólo desagüe de agua primario Seule évacuation primaire SEALING ADVICE HORIZONTAL OUTLET M1 Consejo de sellado Conseil pour étanchéifier ...

Page 20: ...20 M line Only apply with waterproofing of the entire shower floor WITH SECONDARY UNDERTILE DRAINAGE Con desagüe de agua secundario Avec évacuation secondairee ...

Page 21: ...21 M line 1 3 2 4 5 CLEANING VERTICAL OUTLET M4 Limpieza Nettoyage du siphon ...

Page 22: ...22 M line 1 3 2 CLEANING HORIZONTAL OUTLET M1 Limpieza Nettoyage du siphon ...

Page 23: ...ness In order to prevent hollow spaces all empty space beneath the drain must be completely filled up and sealed with floor pavement up to the top edge of the drain flange The seal must be in compliance with the state and local standards When tiles are being fitted the pitch of the tiles min 2 per 3 3 1m1 in the shower must always be sloped towards the drain The tiles should be laid level or 3 64 ...

Page 24: ...clive del desagüe sea suficiente Controle la estanqueidad del sistema de desagüe de la ducha y de las conexiones del desagüe Llenar e impermeabilizar el cuerpo del drenaje completamente hasta el borde superior de la brida y el solado para que quede estanco y evitar espacios vacíos Al colocar las baldosas del suelo el desnivel de las baldosas mínimo 2 cada m1 del área de la ducha siempre debe corre...

Page 25: ...ttre en œuvre le mortier de chape sous toute la surface du corps du caniveau jusqu à l arête supérieure de la bride et de le tasser L étanchéité sera réalisée suivant les règles de l art conformément à la fiche ZDB 8 2012 Étanchéifications composites En cas d utilisation d autres matériaux d étanchéité à titre d alternative il est nécessaire de tenir compte des informations produit des fabricants ...

Page 26: ...26 M line INSTALLATION NOTES Notas de instalación Notes d installation ...

Page 27: ...27 M line INSTALLATION NOTES Notas de instalación Notes d installation ...

Page 28: ...l 31 0 541 200800 email info esspost com www easydrain com 2019 rev 1 ESS PRODUCTS ARE PATENTED AND REGISTRATED TRADEMARKS MADE BY ESS Sales Easy Drain USA Collection 561 Acom Street Unit M Deer Park NY 11729 T 001 888 317 7927 F 001 888 488 1617 email sales usa esspost com www easydrainusa com ...

Reviews: