background image

 

29/05/2013   

     

 

                                            

                                                    

 

 
 
 
 
 

 

 
 
 
 
 
 
 

User’s manual 

 

Summary of Contents for GSM400

Page 1: ...29 05 2013 User s manual ...

Page 2: ... user The User shall be responsible for defects arising from the use of the product Esse ti shall only be responsible for defects according to and within the limitations set by the Presidential Decree dated 24 05 1988 no 224 fulfilling the EEC directive no 85 374 on the harmonization of statutory and administrative regulations of the Member States on the liability for damages arising from defectiv...

Page 3: ...tallation recommendations 12 Absorption chart 12 PROGRAMMING via telephone 13 Voltage of the telephone line 14 Use mode 15 Interdigit dialling time 16 Dialling codes 17 CLIP setting 19 CLIR setting 21 Permanent setting 21 Temporary setting 22 Roaming setting 23 Setting telephone number for notification service 25 setting the administrator telephone number 27 Programming password 28 Low battery che...

Page 4: ...41 Notification message format 43 SERVICES 44 Incoming calls 44 Outgoing calls 44 Measuring the signal level 45 reading the battery status 46 Reading Automatic converter numbers 47 RS232 PORT 48 Connection example 49 SIGNALS 50 Tones 50 Call signals 51 LED 51 Status indicator LED red 51 GSM signal indicator LED green 51 NOTE 53 WARRANTY CONDITIONS 55 WARRANTY CERTIFICATE 56 ...

Page 5: ...ing maintenance etc Always refer to an authorized service centre for repair The device must be installed in a ventilated place making sure that the ventilation slots are never obstructed Do not install the product in environments with risk of explosion Make sure that the product has been installed as required Do not introduce objects liquids or powders inside the product Do not use sprays inside t...

Page 6: ...MF tones Remote programming via SMS Display of caller identification CLIP CLIR Roaming setting Low battery check only available on models GC and DATA Low battery notification by SMS Measurement of GSM signal level Automatic converter of selected telephone number Receiver and transmitter gain adjustment Remote reboot function GSM signal indicator LED Status indicator LED Dual Band GSM module 2W tra...

Page 7: ...indicating device operation status red D Telephone line output RJ11 connector for telephone set connection or PABX analogue line connection E 230Vac external adapter input F Telephone line output terminal block for connection of autodialer PABX analogue line G 12Vdc power supply terminal block H Backup battery connector GC and DATA models only I RS232 port DATA model only ...

Page 8: ...it unblocks and lift it Carefully slide the SIM card into its housing cover Lower the SIM card housing cover and shift it upward until it blocks WARNING The SIM Card PIN must be DISABLED If the PIN is enabled it must be disabled through a mobile phone Inserting the antenna Screw the antenna cable in to the connector on the top of the module WARNING Do not install the product near other electric or...

Page 9: ...ut terminals of a PABX or autodialer using the TEL terminal F in the picture at page 7 Connection to the power supply Power supply via 230Vac external adapter Connect the external adapter to the specific input E in the picture at page 7 Connect the backup batteries if present to the dedicated input H in the picture at page 7 Close the gateway cover or 12Vdc power supply Connect the power supply ca...

Page 10: ...d upstream to interrupt power supply in case of fault Turning the GSM400 gateway on Power the GSM400 Wait 15 seconds after power up to give time to the GSM400 to register correctly with the GSM network Make sure the red LED device status flashes briefly once every 3 seconds as shown in chapter SIGNALS Set parameters or make a call If the red LED flashes quicker and stays lit for a longer time see ...

Page 11: ...ere the signal is strong enough Note the signal strength may vary according to the telephone provider Drill two holes with 5 mm diameter on the wall at a distance of 50 mm Insert the 2 fischers and screw down until the screws are at a 5 mm distance from the wall Place the GSM400 gateway onto the two screws through the two back slots ...

Page 12: ...c radio or TV sets Personal Computers wired radio systems etc or magnetic credit cards floppy disks etc devices that could be subjected to RF interference from the module recommended distance from the antenna is min 2 5 m Do not install the GSM400 gateway near medical devices Its operation may cause damage to hearing aids or pacemakers Always make sure that the device operation is permitted in the...

Page 13: ...e password low battery check automatic converter of selected telephone number receiver gain adjustment transmitter gain adjustment Note during programming the interdigit dialling time must not exceed the time set during the Interdigit dialling time programming Once this programmed time has elapsed you will hear the dissuasion tone and you will have to hang up Note at the end of each programming ca...

Page 14: ...rogramming allows you to modify the voltage in the TEL terminal and in the RJ 11 connector A higher voltage may be required for the proper functioning of specific devices Factory default lower voltage 36Vdc option confirm Lift the handset and dial 61 Enter 0 lower voltage 36Vdc 1 higher voltage 52Vdc Dial to confirm After the confirmation tone hang up or enter additional settings Note do not chang...

Page 15: ...analogue telephone set Factory default telephone PABX Setting telephone PABX mode confirm Lift the handset and dial 21 Dial to confirm After the confirmation tone hang up or enter additional settings Setting autodialer mode confirm Lift the handset and dial 22 Dial to confirm After the confirmation tone hang up or enter additional settings ...

Page 16: ...al the telephone number and wait The call will be sent after the interdigit time has elapsed If you wish to use the second way it could be useful to modify the interdigit time in order to quicken the calling procedure Factory default 5 seconds interdigit time confirm Lift the handset and dial 8 Dial the interdigit dialling time 0 interdigit time 10 seconds 1 9 interdigit time from 1 to 9 seconds D...

Page 17: ...or example the international dialling code for Italy whose complete code is 0039 is 00 Factory default 00 international call prefix confirm Lift the handset and dial 08 Dial the international call prefix max 5 digits Dial to confirm After the confirmation tone hang up or carry on with other programmings Country calling code The country calling code is the second part of a country s code For exampl...

Page 18: ...Page 18 country calling code confirm Lift the handset and dial 09 Dial the country calling code max 5 digits Dial to confirm After the confirmation tone hang up or carry on with other programmings ...

Page 19: ... call With this programming you can determine whether to show the date and time of the call in addition to the caller s number Factory default date and time not displayed Activation day month year hh mm confirm Lift the handset and dial 7 1 Dial the day two digits the month two digits and the year two digits Dial Dial the hour two digits dial the minutes two digits Dial to confirm After the confir...

Page 20: ...g time it will be necessary to repeat the activation procedure otherwise the date and time displayed could be incorrect Deactivation confirm Lift the handset and dial 7 0 Dial to confirm After the confirmation tone hang up or carry on with other programmings ...

Page 21: ...n the service provided by your provider option confirm Lift the handset and dial 6 Enter 0 operation based on the service provided by your provider 1 restriction active 2 restriction not active Dial to confirm After the confirmation tone hang up or carry on with other programmings Note if you choose option 1 your telephone number will not appear on the call recipient s display ...

Page 22: ...or the immediately subsequent call confirm Lift the handset and dial 16 Dial to confirm After the confirmation tone hang up or carry on with other programmings Disabling restriction for one call Initial situation CLIR restriction active This programming allows you to deactivate the CLIR restriction for the immediately subsequent call confirm Lift the handset and dial 17 Dial to confirm After the c...

Page 23: ... any calls Such a condition is signalled by the following tone sequence Factory default roaming enabled Note such setting is recommended for use under neighbouring countries areas in order to avoid the undesired selection of foreign operators Note the roaming service is enabled by factory default Enabling roaming service confirm Lift the handset and dial 5 1 Dial to confirm After the confirmation ...

Page 24: ...he GSM400 s operation with any other provider MCC MNC confirm Lift the handset and dial 5 0 Select the specific SIM s provider by dialling the related MCC Mobile Country Code and MNC Mobile Network Code codes Dial to confirm After the confirmation tone hang up or carry on with other programmings ...

Page 25: ...otifications by SMS telephone number telephone number confirm Lift the handset and dial 40 Enter the telephone number to which the notification SMS must be sent Dial Enter again for confirmation the telephone number to which the notification SMS must be sent Dial to confirm After the confirmation tone hang up or carry on with other programmings ...

Page 26: ...ting It allows to delete the telephone number appointed for SMS notifications or warnings confirm Lift the handset and dial 40 Dial to confirm After the confirmation tone hang up or carry on with other programmings ...

Page 27: ...ote once it has been entered the administrator number will receive the notification SMS related to the Automatic converter service telephone number telephone number confirm Lift the handset and dial 18 Enter the administrator telephone number Dial Enter the administrator telephone number again for confirmation Dial to confirm After the confirmation tone hang up or carry on with other programmings ...

Page 28: ... and for Automatic converter service Factory default 0 Note make sure the password has been noted down In case it is lost please contact the nearest technical service center password password confirm Lift the handset and dial 19 Enter the new programming password max 3 digits Dial Enter the new password again for confirmation Dial to confirm After the confirmation tone hang up or carry on with oth...

Page 29: ...ne notification SMS only A new SMS will be sent out if the charge status rises and goes again below the previously set threshold The SMS text is the following Batteria scarica Low battery The low battery check is only available on models GC and DATA The built in backup batteries ensure 8 operating hours in idle mode and 1 operating hour in conversation mode Factory default disabled Enabling It all...

Page 30: ... allows to set the min number of operating hours in idle mode Below this threshold a notification SMS is sent out Factory default 4 hours value confirm Lift the handset and dial 52 Enter the value 0 9 according to the table below 0 1 2 3 4 5 6 7 7h 6h e 30 6h 5h e 30 4h 2h e 30 1h e 30 1h Dial to confirm After the confirmation tone hang up or carry on with other programmings ...

Page 31: ...ling the real one When dialing out a telephone number not associated with any preset number the call will be automatically forwarded to the first preset telephone number Note to enable the Automatic converter service you simply need to preset one telephone number to disable this service all preset telephone numbers must be deleted Example preset table Location Selected tel number Preset tel number...

Page 32: ...sent out by GSM400 password location telephone number telephone number confirmation Lift the handset and dial 26 Enter the programming password Dial Enter the desired telephone number location from 1 to 5 in the related table Dial Enter the telephone number to be preset Dial Enter again the telephone number to be preset Dial to confirm the entered parameter After the confirmation tone hang up or c...

Page 33: ...cation of the telephone number to be deleted Dial to confirm After the confirmation tone hang up or carry on with other programmings Deleting all preset telephone numbers It allows to delete all the preset telephone numbers password confirmation Lift the handset and dial 26 Enter the programming password Dial Dial to confirm After the confirmation tone hang up or carry on with other programmings ...

Page 34: ...d out by auto learning procedure password location telephone number telephone number confirmation Lift the handset and dial 25 Enter the programming password Dial Enter the position of the preset number to be matched 1 to 5 Dial Enter the telephone number to be matched Dial Enter again the telephone number to be matched Dial to confirm the entered parameter After the confirmation tone hang up or c...

Page 35: ... of the telephone number to be deleted 1 to 5 Dial to confirm After the confirmation tone hang up or carry on with other programmings Deleting all previously matched telephone numbers It allows to delete all previously matched telephone numbers associated with preset numbers password confirmation Lift the handset and dial 25 Enter the programming password Dial Dial to confirm After the confirmatio...

Page 36: ...mber If so it will send a call to the preset number if not it will match the selected number to the first available preset number and will make a call to it In case there are not available preset numbers but it s still possible to make associations the selected number will be automatically matched with the first preset number In case all 5 possible associations have been effected the call will be ...

Page 37: ... strictly necessary Transmission Factory default 12dB value confirm Lift the handset and dial 10 Enter the value 1 7 according to the table below 1 2 3 4 5 6 7 4dB 6dB 10dB 12dB 15dB 17dB 18dB Dial to confirm After the confirmation tone hang up or carry on with other programmings Reception Factory default 10dB value confirm Lift the handset and dial 11 Enter the value 1 5 according to the table be...

Page 38: ...Page 38 1 2 3 4 5 14dB 12dB 10dB 8dB 6dB Dial to confirm After the confirmation tone hang up or carry on with other programmings ...

Page 39: ...programmings The factory default values are Telephone line voltage 36Vdc Use mode PABX telephone Interdigit dialling time 5s International call prefix 00 Country calling code 39 CLIP disabled CLIR depends on the provider Roaming enabled Low battery check disabled 4h Transmitter gain 12dB Receiver gain 10dB Note restoring factory default does not modify the password and the settings entered for the...

Page 40: ...n reset the GSM400 gateway at any time without powering it off with the following code confirm Lift the handset and dial 98 Dial to confirm Hang up Note resetting the GSM400 gateway does not modify its programming profile ...

Page 41: ...elephone number that forwarded the programming SMS WARNING Programming outgoing SMS from the Internet may not be successful if the requested format is not respected Message format Each programming SMS must contain the password allowing to access programming and the codes corresponding to the desired settings The message format is required to be as follows ET IG4 xxx c c where ET IG4 programming st...

Page 42: ... 40 Setting administrator number 18 X X X X Deleting administrator number 18 Setting programming password 19 XXX XXX Low battery check enabling 50 Low battery check disabling 51 Low battery check minimum value 52 X Entering preset number 26 XXX X X X X X Deleting preset number 26 XXX X Deleting all preset numbers 26 XXX Reading preset numbers 26 XXX XR Entering selection 25 XXX X X X X X Deleting ...

Page 43: ...rator who previously sent out a programming SMS is the same as the programming message format SMS notifying an accepted command ET IG4 xxx c c SMS notifying a rejected command ET IG4 xxx c cERR Example outgoing SMS to enable low battery check and to set the following incoming notification number 3330123456 Outgoing message text ET IG4 0 50 40 3330123456 3330123456 Message text notifying accepted c...

Page 44: ...SM400 gateway is connected to a telephone Pick up the handset You will hear the dialling tone Dial the telephone number to be called Note once you have dialled the number you can either press to send the number immediately or you can wait for the call to be automatically forwarded once the interdigit dialling time has elapsed by default 5 seconds Note in the event you receive the no signal tone pi...

Page 45: ...Tones Good 4 Tones High Since the signal can be subject to variations we recommend repeating the code 30 2 or 3 times a few seconds apart in order to have a reliable measurement Note in case of low signal we recommend installing the GSM400 in a different area with a better signal Note if you receive the no signal tone it means that the gateway has not been registered correctly by the provider We r...

Page 46: ...lerted The outgoing message text is the following Carica batteria Battery charge x where x is the value corresponding to the minimum number of operating hours guaranteed by the battery in idle mode according to the table at paragraph Low battery check The request will not be accepted an error tone will be received if the low battery check is disabled if the notification number to be alerted has no...

Page 47: ...e XXX programming password X preset number location Reading previously selected numbers The programming code to be contained in the message text must be the following dove XXX programming password X selected number location An answer message will be returned to user or the system administrator who sent out the SMS Example an SMS has been sent out to ascertain the preset number stored at location 1...

Page 48: ...mission between devices equipped with serial communication eg pc and lift controller Note the SIM card must be enabled for data traffic 2 transmission from GSM400 to the connected device 3 GSM400 reception 5 ground Port settings Bits per second 115200 Parity None Data bits 8 Stop bits 1 Flow control None ...

Page 49: ...Page 49 Connection example ...

Page 50: ...d of conversation access to services not permitted Busy Indicates that the called party is busy Confirmation Indicates that the requested service or programming has been accepted Error Indicates that the requested programming has not been accepted GSM signal level Low signal level Medium signal level Good signal level ...

Page 51: ...or LED red Indicates network login in progress or GSM400 not correctly registered to the network or PIN enabled Indicates the GSM400 is correctly registered to the network Indicates connection voice or data in progress GSM signal indicator LED green No signal Low signal level Medium signal level ...

Page 52: ...Page 52 Good signal level High signal level ...

Page 53: ...Page 53 NOTE ...

Page 54: ...GSM400 29 05 2013 ...

Page 55: ...exclusively mean free of charge repair or replacement of components identified as defective in manufacturing or materials including workmanship 4 The warranty shall not apply in case of damages caused by negligence use or installation not compliant with instructions damages caused by interventions of unauthorized personnel damages caused by accidental causes and or user s negligence with particula...

Page 56: ... Model Serial N Dealer s signature and stamp Proof of purchase Purchaser s signature Esse ti s r l Via G Capodaglio 9 62019 Recanati MC ITALY Tel 39 0717506066 1 Fax 39 0717506057 www esse ti it mail assistenza esse ti it ...