HI-PRO 412 RACK (ISDN)
Pagina
37
Actuator relays
Hi-Pro has 2 actuator relays to command loads with up to 10A to 24V
absorption. Use the remote programmer software or the programming codes at
page Errore. Il segnalibro non è definito. to configure the relays.
Note: if the doorphone or ISDN optional board is inserted, relays 1
and 2 are automatically assume the function of a door opener
(door 1 and door 2 respectively), but they may also be used as
actuators dialling the related code.
Connect the door opener mechanisms to the relay contacts (inputs H in
figure page 28) using banana connectors supplied with Hi-Pro.
External Music source
Hi-Pro is projected for the connection of an external music source, which may
be used both as music on-hold and as background music for Responder, DISA
and Voicemail messages.
Esse-ti external source: A50
Remove the 2 screws shown as B and D in figure page 30 and the other
2 on the opposite side.
Remove Hi-Pro 412 Rack (ISDN) cover by sliding towards the rear.
Remove the cable inserted in A50 connector (F in figure page 29) and
connect A50.
Replace the cover.
Tighten the screws removed before.
Note: for activation, please refer to the programming paragraph
“External music source”.
Other music sources
Connection must be realized with the mini-jack supplied with PBX.