background image

 

PROGRAMMING 

Page 10 

BASIC PROGRAMMING

 

HANDSFREE 
CONNECTION 
MODE 
(INST) 

 

 

handsfree activation by “Handsfree activation”

 

       code 

 automatic handsfree activation

 

ALARM RESET 
MODE 
(INST) 

 

 

automatic reset

 

 

alarm reset by “End” code

 

DATE 
(INST) 

 

weekday 

(dd) 

(mm) 

 (yy

)

 

 SUNDAY 

 MONDAY 

 TUESDAY 

 WEDNESDAY 

 THURSDAY 

 FRIDAY 

 SATURDAY 

TIME 
(INST) 

 

 (hhmm; from 0000 to 2359) 

RECORD 
MESSAGES 
(INST) 

 

 identification message  

(max. 22 sec.) 

(beep) 

record 

 courtesy message  

(max. 22 sec.) 

LISTEN TO 
MESSAGES 
(INST/OPER) 

 

 identification message 

(listen) 

 courtesy message 

INSTALLATION 
TYPE 
(INST) 

 

 1 active speaker unit  

 2 active speaker unit 

DEAD BATTERY 
ALARM 
(INST) 

 

 disabled alarm 

 enabled alarm 

NO MAINS 
POWER SUPPLY 
ALARM  
(INST) 

 

 disabled alarm  

 from 01 to 99 = enabled alarm with XX minutes  

           delay 

DIAGNOSTICS 
ALARM 
(INST/OPER) 

 

 disabled alarm 

 enabled alarm 

Summary of Contents for ST56 INTL

Page 1: ...Alarm system for elevators compliant with the European Standard EN 81 28 2018 ST56 INTL QUICK GUIDE To download User guides in foreign languages please scan the QR code or visit https www esse ti it...

Page 2: ...d and GSM200 C signal strength green C Connector for Esse ti power supply 12 Vdc D Connectors for optional relay board E Serial plug for connection to elevator CPU F Reset pushbutton G RJ11 connector...

Page 3: ...VV2 Common speaker unit 2 VV1 Output speaker unit 1 VV1 Common speaker unit 1 TEL Local Telephone Optional PSTN line board LTI PSTN line or universal gateway input Ground terminal Optional relay boar...

Page 4: ...eans of the supplied cable PSTN line or universal gateway 2G 3G 4G Remove the jumpers set in the dedicated connector for the PSTN line board s picture 2 Insert the optional board in the dedicated conn...

Page 5: ...the elevator location dial pronounce the message and hang up To listen again to the previous message lift the local telephone handset and dial Make an external call to check the telephone line presen...

Page 6: ...tic reset Hang up or press to end the alarm Remark you can choose the 1st or the 2nd mode with the Alarm reset mode programming code 77 In case it should not be possible to stop the alarm procedure re...

Page 7: ...Page 7 WIRING DIAGRAMS WIRING DIAGRAMS Example connection...

Page 8: ...WIRING DIAGRAMS Page 8 Example connection...

Page 9: ...by default EXITING THE PROGRAMMING INSTALLER or OPERATOR PASSWORD by default TYPE OF TELEPHONE LINE INST PSTN line or universal gateway 2G 3G 4G with optional board GSM200 C module TELEPHONE NUMBERS...

Page 10: ...SATURDAY TIME INST hhmm from 0000 to 2359 RECORD MESSAGES INST identification message max 22 sec beep record courtesy message max 22 sec LISTEN TO MESSAGES INST OPER identification message listen cour...

Page 11: ...abled EN 81 28 2004 Make a test call manually SPEAKER UNIT VOLUMES INST OPER SPEAKER UNIT 1 loudspeaker s volume factory default 3 SPEAKER UNIT 2 microphone s sensitivity factory default 8 MESSAGES VO...

Page 12: ...y Switzerland Portugal Poland Bulgaria England Israel Greece Austria digital Germany France Australia Russia Hungary Netherlands Croatia EMERGENCY BUTTONS NORMALLY OPEN CLOSED INST closed open EMERGEN...

Page 13: ...from 1 to 3 digits factory default 5 HANDSFREE ACTIVATION CODE INST from 1 to 3 digits factory default 0 END CODE INST from 1 to 3 digits factory default 9 EXCLUSION CODE INST from 1 to 3 digits facto...

Page 14: ...put AR active for mains failure RELAY 2 door opener active as long as the emergency alarm progresses active as long as the buttons are pressed RELAY INTERMITTENCE INST relay 1 steady state relay 2 ste...

Page 15: ...sponding to the desired settings The message format is required to be as follows ET HL3 xxx n n n n n n Where ET HL3 programming string start xxx password string default xxx 0 n n programming code e g...

Page 16: ...returned after programming depending on the characteristics of the SMS recipient devices Examples Desired settings date Thursday 04 02 16 hour 21 15 automatic test call enabled Programming message ET...

Page 17: ...LS TELEPHONE NUMBER DOOR OPENER RELAY with optional board RELAY 1 RELAY 2 Remote use with ST56 in stand by Call the ST56 and wait for the answer After a short series of DTMF tones followed by the elev...

Page 18: ...l operation no alarm Alarm Battery disconnected or low battery max 1 hour operation in idle state LED signalling GSM200 C signal strength No signal Low signal level connection not guaranteed Medium si...

Page 19: ...Missed test call notification The Given alarm indicator light and the Received alarm indicator light flash in opposition to indicate the failure of the automatic test call The flashing sequence ends a...

Page 20: ...by Esse ti S r l declares that the equipment type ST 56 is in compliance with Directives 2014 30 EU 2014 33 EU 2014 35 EU The full text of the EU declaration of conformity is available from the follow...

Page 21: ...Page 21 NOTE NOTE...

Page 22: ...NOTE Page 22...

Page 23: ...Page 23 NOTE...

Page 24: ...Esse ti s r l Via G Capodaglio 9 62019 Recanati MC ITALY Tel 39 071 7506066 Fax 39 071 7506057 www esse ti it support esse ti it...