17
Quick Setup Guide
The Operational Modes for IPD and PIR Devices
The WeR@Home™ System has two operational modes for the IPD and PIR devices:
●
Walk Test Mode
●
Normal Operation Mode
Walk Test Mode
The Walk Test Mode is a test mode used following a device power-up for initial system testing of the device. This test runs for
about 30 minutes. During this period, the device continues to send event reports to the Hub when detecting actual events.
No hibernation period occurs during the 30-minute test.
Normal Operation Mode
Following the completion of the Walk Test, the system switches the IPD or PIR device to Normal Operation Mode.
Each time the IPD or PIR device detects an activity
●
The device sends an event report to the Hub.
●
The device LED turns Red.
●
The device switches to a 2-minute hibernation period.
The IPD or PIR device does not transmit events to the Hub during this period.
If activity is detected during the hibernation period,
●
The device does not send event reports to the Hub.
●
The device LED remains off.
●
The 2-minute hibernation period restarts.
This process repeats until there is no activity detection for the entire 2-minute period.
After the completion of the 2-minute hibernation period, the IPD or PIR device resumes normal operation.
Test the Door/Window Sensor (MGL)
To verify proper operation of the MGL, open and close the door or window and watch the MGL LED. The LED should turn
Red
when the door or window is open or turn
Green
when the door or window is closed.
Test Your WeR@Home™ System