Troubleshooting Instructions:
Problem
Cause
Remedy
1.Unit does not draw
a.Clogged suction tube strainer
a. Clean or replace
concentrate
b. Metering tip orificeobstructed
b. Rinse tip or replace: Do not attempt
to clean: may alter size of orifice
c. Water pressure too low
c. Minimum 25 PSI required
d. Mineral deposits in
d. Back flush unit. Remove container,
barrel of foamer
tube and metering tip. Put finger over
barrel suction opening. Apply minimal
water pressure through garden hose at
nozzle of barrel to be flushed.
d. Descale foamer by soaking in weak
descaling solution.
e. Clogged water inlet
e. Clean or replace strainer.
strainer (low water flow)
2. Weak foaming action
a. Clogged water inlet strainer
a. Clean or replace.
b. Water pressure too low
b. Minimum 25 PSI required
c. Water temperature too high
c. Use lower temp water source. (Concentrate
flow decreases above 140º F water)
If above steps fail to produce good concentrate draw and/or foaming action, replace lid assembly. See
component chart below.