Troubleshooting Instructions:

Problem

Cause

Remedy

1.Unit does not draw

a.Clogged suction tube strainer

a. Clean or replace

concentrate

b. Metering tip orificeobstructed

b. Rinse tip or replace: Do not attempt

to clean: may alter size of orifice

c. Water pressure too low

c. Minimum 25 PSI required

d. Mineral deposits in 

d. Back flush unit. Remove container, 

barrel of foamer

tube and metering tip. Put finger over 
barrel suction opening. Apply minimal 
water pressure through garden hose at 
nozzle of barrel to be flushed.

d. Descale foamer by soaking in weak

descaling solution. 

e. Clogged water inlet

e. Clean or replace strainer.

strainer (low water flow)

2. Weak foaming action

a. Clogged water inlet strainer

a. Clean or replace.

b. Water pressure too low

b. Minimum 25 PSI required

c. Water temperature too high

c. Use lower temp water source. (Concentrate

flow decreases above 140º F water)

If above steps fail to produce good concentrate draw and/or foaming action, replace lid assembly. See 
component chart below.

KEY 

PART NO.

DESCRIPTION

1

10083713

Spray gun & quick disconnect

2a

10061501

Foamer lid assembly

b

10061502

Sprayer lid assembly

3

688201

Concentrate container - 96 oz.

688202

Concentrate container - 48 oz.

4

10027001 

Lt. Purple ultra lean metering tip

5

500808

Suction tube, 8" 

6

609600

Foot strainer