Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
8
c. (OPTIONAL) To change the illumination on the SKE-26
only, enter the code as follows:
Code Standby Mode
Normal Operation
210 # Off (factory default) Off (factory default)
211 # Off
Dim
212 # Off
Bright
213 # Dim
Dim
214 # Dim
Bright
You should hear 3 beeps indicating successful configuration
(the RED LED will continue to flash and the GREEN LED will be
solid). If you hear a long error beep, re-enter the configuration
number followed by #.
7. Remove power.
8. Remove configuration jumper.
9. Re-apply power.