20
Modify a User by User ID
a. Enter
2 #
b. Enter the User ID (1 to 500) for the User to be modified, followed
by
#
c. To change this User’s Code, enter the New User Code followed by
#
- OR, see step d below -
d. To keep this User’s Code, enter
#
. Then, enter the desired User
Authroization, followed by
#
. (Repeat for additional authorizations
or skip to Step e for no authorizations.)
Code User Authorization
1
Latching Authorization
2
Program or Delete Users Authorization
3
Output A Authorization (see notes)
4
2nd Door (see notes)
5
Output B Authorization (see notes)
6
3rd Door (see notes)
7
24-hour Access (see notes)
e. Enter
#
to complete programming for this User.
f. To modify an additional User, return to Step b.
g. If no more Users are to be modified, enter
*
*
and return to Step
3, or if you have completed all User Programming, enter
*
*
a second time to complete programming sequence and reset
system to normal operation.
Modify a User by User Code
a. Enter
3 #
b. Enter the User Code for the User you wish to modify, followed
by
#
c. To change this User’s Code, enter the New User Code followed by
#
- OR, see step d on next page -