Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
4
PINK- Remote Bypass
Connect a Normally Open push button between PINK and BLACK to
trigger the main output for its normal Door Open Time setting.
ORANGE- Set Up Programming
Momentarily connecting ORANGE to BLACK puts the unit in Set Up
Mode (same as entering * 3, Master Code #).
BROWN- 24-hour Access
If Time Clock is enabled in Set up (page 16) and the BROWN wire
is grounded, all codes work normally. When the BROWN wire is
not grounded, only those codes with 24-hour Access Authorization
(page 17) will function.
Internal Relay Wiring Diagram
12-24VDC
Power
Supply
RED
BLACK
YELLOW
BLUE
VIOLET
GRAY
FAIL
SECURE
FAIL
SAFE
MOV
K
E
Y
P
A
D
12-24VDC
Power
Supply
VIOLET
YELLOW
BLACK
RED
BLUE
K
E
Y
D
P
A
Across
Existing
Push
Button
TYPICAL LOCK HOOK-UP
TYPICAL GARAGE DOOR
or GATE HOOK-UP
+
-
+
-
MOV
TAN Earth Ground
TAN Earth Ground