4.7 Preventing dust hazards
CAUTION
Damage due to dust release
Maintenance, cleaning, repair and emptying work may be done only by
expert personnel.
Wear personal protective equipment.
-
Respirator mask (particle filter class P3)
-
Protective clothing
-
Protective gloves
-
Eye protection
Set up locally filtered forced-air ventilation where the product is being
maintained, inspected or cleaned.
Operate the product only with the complete filtration system.
Seal the intake port with a sealing plug so it is dust-tight when transporting.
CAUTION
Damage due to dust build-up in the pipe system
Check the connected piping system regularly for dust deposits.
Observe the minimum air speed required for your application and the
resulting minimum airflow volume.
When opening and emptying the collection drawer, dust
inhalation cannot be ruled out. That is why all servicing, cleaning
and maintenance procedures, including the emptying of the
collection drawer, are only to be performed by specialist
personnel with personal protective equipment.
The people assigned to cleaning work must be instructed with
regard to the aspirated toxic materials. Harm to bystanders and
the environment must be prevented by all means. After the
maintenance has been carried out, the maintenance area must
be thoroughly cleaned.