First Run
E-S 1000D Series Instruction Manual
4.1
PUSH 1 or PUSH 2 to increase or decrease the parameter. Then press SET button to move
to the next parameter.
1. Press SET button to begin.
2. LED shows P1:
Press Push 1 to get P1 setting to 30.
3. Press SET button.
4. LED shows P2:
Press Push 1 to get P2 setting to 10.
5. Press SET button.
6. LED shows P3:
Press Push 1 to get P3 setting to 30.
7. Press SET button.
8. LED shows P4:
Press Push 1 to get P4 setting to 3.
9. Press SET button.
10. LED shows P5:
Press Push 1 to get P5 setting to 2.
11. Press SET button.
12. LED shows P6:
Press Push 1 to get P6 setting to 10.
13. Press SET to finish. You should hear 3 beeps; this indicates parameter programming is
finished.
This is our recommended procedure to run the gate for the first time.
Set
Push 1
Push 2
Manually detach the end of the gate opener, then
turn shaft half-way and re-attach. Activate using
Push 1 button (as shown above) The gate should
run open. Press Push 1 again and it should run
closed.
The gate is now set up for regular usage.
Make sure the first
switch is turned
off (down)
Summary of Contents for E-S 1000D Series
Page 4: ...Section 1 Review of Specifications Warnings and Tools E S 1000D Series Instruction Manual ...
Page 5: ......
Page 10: ...Section 2 Installation of Mounting Brackets E S 1000D Series Instruction Manual ...
Page 11: ......
Page 21: ...Section 3 Gate Operator Mounting Wiring Motors Power E S 1000D Series Instruction Manual ...
Page 22: ......
Page 32: ...Section 4 Start Up Operation E S 1000D Series Instruction Manual ...
Page 33: ......
Page 37: ...Section 5 Maintenance Troubleshooting Accessories E S 1000D Series Instruction Manual ...
Page 38: ......