Troubleshooting
E-S 1000D Series Instruction Manual
5.3
The gate opener is not stopping on the limit switches:
Remove all pre-installed jumpers from the limit switch terminals that have limits
going to them. The slave gate terminals come pre-jumped for single operation, if
you are using a dual system pay particular attention to this detail and remove the
jumpers when you put your limit switches in.
The limits are wired incorrectlybe sure that you are following the correct
wiring diagram for pull to open or push to open.
For dual gates check that the delay between leafs is 2 or above. If both limits
are triggered simultaneously there is a chance a limit could be missed.
One or both arms are not moving:
If displays LU, the battery is too low & it is in low voltage lock out. Replace or
charge battery.
Check to be sure wiring color pattern matches the installation (Example: push
to open wiring for a push to open installation) - If the limits or motor are wiring
opposite the installation the board will believe it is closed or open when it is
actually the opposite and the arms will never move.
Check the limit wires are correctly in the terminal blocks. The terminal blocks
come with the terminal clamps closed - however when the terminal clamps are
closed there is a small space below them one could mistake as place to insert a
wire. If this is done then conductivity of the connection will never be reached.
General fixes for user to understand operation.
- Unhook the gate opener arm and move it to the half way position. Change the
run time to a low number (example: 2). Run the operator repeatedly.
- The operator should run one direction for a 2 count and then the other for a 2
count. After you feel you have it following the run time correctly and swinging
level and easily, then start incrementally lengthening the run time.
- Eventually the run time will allow the operator arm to reach both limit switches
and your setup is complete.
Dual gate - Only one arm moves:
Check your dual settings - if the dip switch is changed to dual with the power on the
setting will not take effect, turn the power off and then back on to have the dual dip
switch take effect.
NOTE:
If one leaf of a dual gate ever reaches its end limit before the
other leaf starts moving, the leaf that hasnt started moving will not begin: correct this
by cycling the gates again and let it travel the full stroke or decrease the delay
between leafs. The options are 0-9 seconds delay.
Summary of Contents for E-S 1000D Series
Page 4: ...Section 1 Review of Specifications Warnings and Tools E S 1000D Series Instruction Manual ...
Page 5: ......
Page 10: ...Section 2 Installation of Mounting Brackets E S 1000D Series Instruction Manual ...
Page 11: ......
Page 21: ...Section 3 Gate Operator Mounting Wiring Motors Power E S 1000D Series Instruction Manual ...
Page 22: ......
Page 32: ...Section 4 Start Up Operation E S 1000D Series Instruction Manual ...
Page 33: ......
Page 37: ...Section 5 Maintenance Troubleshooting Accessories E S 1000D Series Instruction Manual ...
Page 38: ......