5.8
Control Board Overview
CAUTION!
Do not run 110V AC power direct to the board. This
will cause permanent damage to both boards and void your
warranty. Caution!
Display Indicators:
Lights off on board & stand by / normal operation
Lower right hand “dots” flashing normal pace:
Active / Awaiting command
EL:
Sending voltage to EL terminals (electric lock)
OP:
Opening cycle
AU:
Auto-reclose countdown
CL:
Closing cycle
PH:
Photo cell disruption
Buzzer / Obstructions:
If the gate(s) come in contact with an obstruction the
gate(s) will reverse direction for 2 seconds and stop to
allow the obstacle to be cleared from the gate path.
If the gate(s) obstructs 3 times in a row the gate(s) will
go into a hard shutdown mode and a buzzer alarm will
sound. At this point no accessories or remotes will be
able to activate the gate opener until the gate opener
is reset by disconnecting primary power battery.