Estate Swing E-SC 1600 / E-SC 1602 Column Mounted Gate Opener Instructions.
12
If you are not using a safety device like a photo
eye or safety loop the Photocell terminal must
remain jumped to the GND terminal.
Dip Switches
—To change any dip switches, you must turn the power off
before changing the setting.
ON:
Auto-close on (the gate will re-close from
the open position after a time set in the
programming section)
OFF:
Auto-Close off
ON:
Dual gate opener (2 motors)
OFF:
Single gate opener (1 motor)
ON:
Electric Lock being used
OFF:
Electric Lock not used
IMPORTANT:
We recommend before turning the gate opener
on for the first time to have dip switch 1 OFF. If the dip switch is
set to on, the gate will auto-reclose after turning it on without any
intentional activation on your part.
1.
2.
3.
Photo jumped to GND
Temporary Safety Jumpers & Dip Switch Settings