Accessory Wiring
26
Photo Eye, Safety Edge, Safety Loop:
Normally Closed (NC) of safety device
= Photo ter minal of PHOTO block on gate opener control board.
Common (COM) or Ground (GND) of safety device
= GND ter minal of PHOTO block on gate opener con-
trol board.
12V Power positive (+) or (12V) or (PWR) of safety device
= V+ ter minal of PHOTO block on gate opener
control board.
12V Power Negative (-) or (GND) or (PWR) of safety device
= GND ter minal of PHOTO block on gate
opener control board.
*Remove safety jumper from PHOTO terminal if using a safety device.
*12V is not a misprint, the V+ terminal has a 12V output.
Solenoid Gate Lock:
Positive Lead of lock
= A ter minal of E_LOCK block on gate opener control board.
Negative Lead of lock
= B ter minal of E_LOCK block on gate opener control board.
Magnetic Gate Lock:
Magnetic gate lock s must have their own power supply and their own
relay.
Coil of relay for magnetic lock
= A ter minal of E_LOCK block on gate opener control board.
Coil of relay for magnetic lock
= B ter minal of E_LOCK block on gate opener control board.
Connect positive lead of the power supply directly to the positive lead of the mag lock.
Connect negative lead of the power supply to the N/C terminal of the relay.
Connect the COM terminal of the relay to the negative lead of the mag lock.