Turbine System
The Turbine System has one air hose outlet on the side of the unit and is designed to run
one spray gun.
The turbine will pump the required air flow to apply the “Dihydroxyacetone (DHA)” solution.
This turbine will provide air flow at a rate over 35 CFM at 3.5 PSI. A full body spray tan can
be achieved in less than 2 minutes,
You can replace the turbine pumps filter. The filter is reusable. To clean, rinse under water
and allow to air dry before using it again.
Testing and Adjusting the Spray Machine
1.
Ensure you have assembled the machine as per the Assembly section of this user
guide.
2.
If you are the recipient of the spray, ensure there is another person to help you
operate the machine.
3.
Remove the bottle from the gun. For this first test, add clean water into the bottle
and attach it onto the gun.
4.
Connect Turbine System to a power outlet. Press the On/Off button to turn on the
machine. This provides a continuous source of clean, warm, dry, low-pressure
turbine air.
5.
Adjust the air cap on the gun. Turn the Fluid Control Knob all the way in clockwise
direction.
6.
Aim the gun towards a sink, towel, or another receptacle to collect the water and
pull the trigger. While the gun is triggered and air and water are flowing, you can
twist the Fluid Control Knob in the counter-clockwise direction to trigger the flow of
solution.
7.
Turn the knob in counter-clockwise direction one or two times to produces a round
pattern. Turn it for two or three times to produce a tall, oval pattern. Test this by
spraying on paper as you make your final adjustments.
Notes:
•
The optimum adjustment for the Fluid Control Knob is one or two turns in
counter-clockwise direction. Adjusting it all the way in that direction may stop
the flow of solution from the gun.
•
If you turn the Fluid Control Knobs in the counter-clockwise direction beyond
the point of maximum trigger, you may remove the knob assembly from the
spray gun body. If this happens, simply press the knob assembly back in
against the spring pressure, align the threads and turn clockwise to a normal
adjustment position.